Code
6030
Broken fuser thermistor wire
Input from fuser thermistor is 0 (A/D
value).
6400
Zero cross signal error
The zero cross signal does not reach the
control PWB for specified time.
F000
Control PWB - Operation panel PWB
communication error
F010
Control PWB checksum error
Contents
Causes
Check procedures/corrective measures
Poor contact in the
Reinsert the connector (See page 1-5-16).
fuser thermistor
connector termi-
nals.
Broken fuser ther-
Replace the fuser unit (See page 1-5-16).
mistor wire.
Fuser thermistor
Replace the fuser unit (See page 1-5-16).
installed incor-
rectly.
Fuser thermal cut-
Replace the fuser unit (See page 1-5-16).
out triggered.
Fuser heater lamp
Replace the fuser unit (See page 1-5-16).
installed incor-
rectly.
Broken fuser
Replace the fuser unit (See page 1-5-16).
heater lamp wire.
Defective harness
Reinsert the connector. Also check for conti-
between high volt-
nuity within the connector harness. If none,
age PWB (YC202)
remedy or replace the harness (See page 1-
and control PWB
5-24).
(YC311), or
improper connec-
tor insertion.
Defective harness
Reinsert the connector. Also check for conti-
between power
nuity within the connector harness. If none,
source PWB
remedy or replace the harness (See page 1-
(YC103) and high
5-24).
voltage PWB
(YC201), or
improper connec-
tor insertion.
Defective power
Replace the power source PWB (See page
source PWB.
1-5-22).
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Defective harness
Reinsert the connector. Also check for conti-
between operation
nuity within the connector harness. If none,
panel PWB (YC1)
remedy or replace the harness (See page 1-
and control PWB
5-24).
(YC7), or improper
connector inser-
tion.
Defective opera-
Replace the operation panel PWB.
tion panel PWB.
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Defective code
Turn the power switch off/on to restart the
ROM (flash mem-
printer. If the error is not resolved, replace
ory).
the control PWB (See page 1-5-19).
Defective control
Replace the control PWB (See page 1-5-
PWB.
19).
Remarks
2H4
1-4-5