ASIC test

This setting initiates a scan of the scanner ASIC's memory.
To perform this test, do the following:
1
Navigate to Scanner Tests > ACIS Tests.
2
Select ACIS Tests.
3
The test executes. While this test executes, the screen displays ASIC Test Running.... If the scanner ASIC
passed the test, then the panel posts ASIC Test Passed. Rebooting.... If the scanner ASIC failed the
test, then the panel posts ASIC Test Failed. Rebooting....

Motor tests

The motor tests allow you to test the functionality of the motors in the ADF unit.
ADF pick
When Motor On is selected, the device runs the pick motor continuously for five seconds and then automatically stops
the motor.
To perform this test, do the following:
1
Navigate to Scanner Tests > Motor Tests.
2
Select ADF pick.
3
The test will run if it is working properly.
Flatbed motor scanner
Motor On is selected, the device moves the flatbed scanner along the entire flatbed scanner path (that is, to the far
wall and back to the Home position) and then automatically stops at the Home position.
To perform this test, do the following:
1
Navigate to Scanner Tests > Motor Tests.
2
Select Flatbed Scanner Motor.
3
The test will run.
ADF feed motor forward
When Motor On is selected, the device runs the motor forward continuously until Motor Off is selected.
To perform this test, do the following:
1
Navigate to Scanner Tests > Motor Tests.
2
Select ADF Feed Motor Forward.
3
The test will run.