Parameter List - Mitsubishi Electric FR-A520-0.4K -55K Instruction Manual

Transistorized inverter, high function & low acoustic noise
Table of Contents

Advertisement

4.1 Parameter List

4 PARAMETER
4.1 Parameter List
Func-
Parameter
tion
Number
0
Torque boost (Note 1)
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation frequency
11
DC injection brake operation time
12
DC injection brake voltage
13
Starting frequency
14
Load pattern selection (Note 1)
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High-speed maximum frequency
19
Base frequency voltage (Note 1)
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level
Stall prevention operation level at double
23
speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
28
Multi-speed input compensation
29
Acceleration/deceleration pattern
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost (Note 1)
47
Second V/F (base frequency) (Note 1)
48
Second stall prevention operation current
Second stall prevention operation
49
frequency
50
Second output frequency detection
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Setting Range
0 to 30%
0 to 120Hz
0 to 120Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600 s/
0 to 360 s
0 to 3600 s/
0 to 360 s
0 to 500A
0 to 120Hz, 9999
0 to 10 s, 8888
0 to 30%
0 to 60Hz
0 to 5
0 to 400Hz
0 to 3600 s/
0 to 360 s
0,2
120 to 400Hz
0 to 1000V, 8888, 9999
1 to 400Hz
0,1
0 to 200%, 9999
0 to 200%, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0, 1
0, 1, 2, 3
0, 1, 2
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0,1 to 9998
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
0 to 3600 s/
0 to 360 s
0 to 3600 s/0 to 360 s,
9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 200%
0 to 400Hz, 9999
0 to 400Hz
57
PARAMETERS
Minimum
Refer
Factory Setting
Setting
〈EC Version〉
Increments
Page:
6%/4%/3%/2%
0.1%
(Note 9)
0.01Hz
120Hz
0.01Hz
0Hz
60Hz 〈50Hz〉
0.01Hz
0.01Hz
60Hz
0.01Hz
30Hz
0.01Hz
10Hz
0.1 s/
5 s/15 s
0.01 s
(Note 6)
0.1 s/
5 s/15 s
0.01 s
(Note 6)
Rated output
0.01A
current
0.01Hz
3Hz
0.1 s
0.5 s
0.1%
4%/2% (Note 6)
0.01Hz
0.5Hz
1
0
0.01Hz
5Hz
0.1 s/
0.5 s
0.01 s
1
0
0.01Hz
120Hz
9999 〈8888〉
0.1V
60Hz 〈50Hz〉
0.01Hz
1
0
0.1%
150%
0.1%
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
1
0
1
0
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
0.1%
10%
0.01Hz
6Hz
0.01Hz
9999
0.1 s/0.01 s
5 s
0.1 s/0.01 s
9999
0.1%
9999
0.01Hz
9999
0.1%
150%
0.01
0
0.01Hz
30Hz
To
63
64
64
65
66
66
66
67
67
68
69
69
69
70
70
71
71
72
72
72
72
72
73
73
74
74
74
74
74
75
76
77
77
77
77
77
77
78
79
79
79
80
80
80
80
80
80
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents