Alarm Code Output Selection (Pr. 76) - Mitsubishi Electric FR-A520-0.4K -55K Instruction Manual

Transistorized inverter, high function & low acoustic noise
Table of Contents

Advertisement

z

Alarm code output selection (Pr. 76)

Pr. 76 "alarm code output selection"
When an alarm occurs, its code can be output as a 4-bit digital signal from the open collector output
terminals. When programmed operation has been selected, this parameter also serves to output a group
operation signal.
The alarm code can read by a programmable controller etc to show its remedy on a display. Also you can
look at the progress of programmed operation.
Parameter
Factory Setting
Number
76
0
<Setting>
·
Alarm code output
Pr. 76 Setting
SU
0
1
Alarm code bit 3
When an alarm occurs, an alarm code signal is output. (Output signal is the same as in 1.)
2
When operation is normal, an operation status signal is output. (Output signal is the same as in 0.)
3
(during programmed
Output at time-out
operation)
Note: 1. For alarm code definitions, refer to page 178.
2. The Pr. 76 setting overrides the Pr. 190 to Pr. 195 settings. Therefore, if you assign other signals
to output terminals SU, IPF, OL and FU using Pr. 190 to Pr. 195, these terminals provide the
output signals as listed above when any of "1 to 3" is set in Pr. 76. This should be noted when
using the functions which use the output signals to exercise control.
Example: When using the brake sequence functions (Pr. 278 to Pr. 285), assign the brake
opening request signal (BOF) to the RUN terminal by setting "20" in Pr. 190.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pr. 79 "operation mode selection"
Pr. 190 to Pr. 195
Pr. 200 to Pr. 231
Setting Range
0 to 3
Output Terminals
IPF
Alarm code is not output. (Depends on Pr. 190 to Pr. 195).
Alarm code bit 2
During group 3 operation
During group 2 operation
98
PARAMETERS
Related parameters
(multi-function outputs)
"programmed operation"
OL
FU
Alarm code bit 1
Alarm code bit 0
During group 1 operation

Hide quick links:

Advertisement

Table of Contents
loading