Electrical Adjustment
Group/
Item Name
Item
12 Image AREA H WIDTH
13 Image AREA V HIGHT
17 Y - GAIN TARGET
21 GAIN torelance
Group 270 CUSTOM(Aspect)
0 Horizontal Scaler
1 Vertical Scaler
2 Connect
3 Position Horizontal
4 Position Vertical
5 Aspect Enable
Group 280 AutoPC Adjsut
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group 290 PanelType
0 GammaL/R-View
1
Group 500 Composite (NTSC) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
7
8
Group 501 Composite (PAL) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
7
8
Group 502 Composite (SECAM) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
7
8
Group 510 SCART(480i)
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
7
8
Group 511 SCART (575i)
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
Function
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of GAIN Adj.
H-Scaler Edit
V-Scaler Edit
Link/Unlink Edit Selection
H-Position Compensation
V-Position Compensation
Aspect Adjustment Enable
Auto-PC Adj Operation Enable if Un-support-
ed Signal Input
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Initial
13
9
200
1
100
100
0
100
100
0
0
1
5
1
1
0
-
668
129
47
456
662
144
59
542
662
144
59
542
668
128
47
456
652
136
59
-75-
Range
Note
0 - 4095
0 - 4095
0 - 255
1 - 255
68 - 132
68 - 132
0 - 1
0: Unlinked Edit, 1: Linked Edit
85 - 115
85 - 115
0 - 1
0: Enable, 1: Disable
0 - 1
0: Enable, 1: Disable
0-3
0 - 10
0 [] <--- -----> 10[Not matched]
0 - 1
0: Executes Fine Phase, 1: Not Execute
0 - 7
0: Effective All Bit,
0 - 3
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3: Disable Lower 3 bit
0: Gamma for L-Turn
0-20
20: Gamma for R-Turn * Read only
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Not used
* Not used
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Not used
* Not used
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Not used
* Not used
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Not used
* Not used
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095