Sanyo PLC-XT35 Service Manual page 69

Chassis no. kp3-xt3500, kp3-xt35l00
Hide thumbs Also See for PLC-XT35:
Table of Contents

Advertisement

Electrical Adjustment
Group/
Item Name
Item
198 G_V_INPUT_STEP_2048
199 G_V_INPUT_STEP_2560
200 G_V_INPUT_STEP_3072
201 G_V_INPUT_STEP_3584
202 G_V_INPUT_STEP_4096
203 B_V_INPUT_STEP_0
204 B_V_INPUT_STEP_512
205 B_V_INPUT_STEP_1024
206 B_V_INPUT_STEP_1536
207 B_V_INPUT_STEP_2048
208 B_V_INPUT_STEP_2560
209 B_V_INPUT_STEP_3072
210 B_V_INPUT_STEP_3584
211 B_V_INPUT_STEP_4096
212 FRPPOL
213 FRP_POS
214 SWAP
215 PRE_COLSHD_SEL
216 HSYNC_FOLLOW
217 DELAY_HSYNC
218 DELAY_VSYNC
219 VSYNC_FOLLOW
220 BLANK_RCENTER
221 BLANK_RSTART
222 BLANK_REND
223 BLANK_GCENTER
224 BLANK_GSTART
225 BLANK_GEND
226 BLANK_BCENTER
227 BLANK_BSTART
228 BLANK_BEND
229 DATA LIMIT_MAX_R
230 DATA LIMIT_MAX_G
231 DATA LIMIT_MAX_B
Group 101 Panel Service(6150/1060)
0 R-LCCOM
1 G-LCCOM
2 B-LCCOM
3 R-LCCOM-Gain
4 G-LCCOM-Gain
5 B-LCCOM-Gain
6 R-LCCOM-Bright
7 G-LCCOM-Bright
8 B-LCCOM-Bright
9 R-LCCOM-Cent
10 G-LCCOM-Cent
11 B-LCCOM-Cent
12 R-ENBX-PW
13 G-ENBX-PW
14 B-ENBX-PW
15 R-DXIN
16 G-DXIN
17 B-DXIN
18 R-CLXIN
19 G-CLXIN
20 B-CLXIN
21 R-ENBX1IN
22 G-ENBX1IN
23 B-ENBX1IN
Group 110 * Not used
Group 200 Option
0 Logo Prohibition (Forced No Brand)
1 RS232C Baudrate
2 PJLink Enable
Function
Logo Prohibition (0: Menu, 1: Forced, 2:
China, 3-9: not used)
Baud Rate
Initial
8
0
1019
0
0
36
28
24
16
8
0
1019
0
0
84
18
1285
0
1
30
16
0
0
128
128
0
128
128
0
128
128
4095
4095
4095
340
340
340
193
193
193
0
0
0
18
18
18
10
10
10
22
22
22
22
22
12
17
17
17
0
0
-69-
Range
Note
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-1023
(MIN<-->MAX Cyclic Operation)
0-4095
0-255
0-2047
0-255
0-1
0-2047
0-255
0-1
0-2047
(MIN<-->MAX Cyclic Operation)
0-255
0-255
0-2047
(MIN<-->MAX Cyclic Operation)
0-255
0-255
0-2047
(MIN<-->MAX Cyclic Operation)
0-255
0-255
0-4095
0-4095
0-4095
0-511
* R-Common center adjustment
0-511
* G-Common center adjustment
0-511
* B-Common center adjustment
0-255
0-255
0-255
0-255
0-255
0-255
0-63
0-63
0-63
0-127
0-127
0-127
0-255
Link with No.18
0-255
Link with No.19
0-255
Link with No.20
0-255
Link with No.15
0-255
Link with No.16
0-255
Link with No.17
0-255
0-255
0-255
0 - 2
Effective after AC On
0 - 2
0: 19200bps, 1: 9600bps, 2: 115200bps
* Not used

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xt35l

Table of Contents