Electrical Adjustment
Group/
Item Name
Item
Group 253 Fan Tem Error Setting (Memorized)
0 Temp A Warning (High)
1 Temp B Warning (High)
2 Temp C Warning (High)
3 Temp B-A Warning (High)
4 Temp C-A Warning (High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
15 Temp A Warning Offset (Temp)
16 Temp B Warning Offset (Temp)
17 Temp C Warning Offset (Temp)
18 Temp B-A Warning Offset (Temp)
19 Temp C-A Warning Offset (Temp)
20 Temp A Warning Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp C Warning Offset (Time)
23 Temp B-A Warning Offset (Time)
24 Temp C-A Warning Offset (Time)
Group 254 Fan Control Range Setting (Temp./REV)
0 High Fan Control Min Temp
1 High Fan Control Max Temp
2 High Fan1 Min
3 High Fan1 Max
4 High Fan2 Min
5 High Fan2 Max
6 High Fan3 Min
7 High Fan3 Max
8 High Fan4 Min
9 High Fan4 Max
10 Normal Fan Control Min Temp
11 Normal Fan Control Max Temp
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
18 Normal Fan4 Min
19 Normal Fan4 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
28 Eco Fan4 Min
29 Eco Fan4 Max
Function
Temp. A to judge the Temp Error at High
(Room)
Temp. A to judge the Temp Error at High
(Lamp)
Temp. A to judge the Temp Error at High
(Panel)
Temp. B-A to judge the Temp Error at High
(Clogging Det.)
Temp. C-A to judge the Temp Error at High
(Clogging Det.)
Temp. A to judge the Temp Error at Normal
(Room)
Temp. A to judge the Temp Error at Normal
(Lamp)
Temp. A to judge the Temp Error at Normal
(Panel)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
Temp. A to judge the Temp Error at Eco (Room)
Temp. A to judge the Temp Error at Eco (Lamp)
Temp. A to judge the Temp Error at Eco (Panel)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Tem.p at High
Fan Operation REV(Min/Max) setting at High
(rpm)
Temp Senser Control Start/End Tem.p at
Normal
Fan Operation REV(Min/Max) setting at
Normal (rpm)
Temp Senser Control Start/End Tem.p at Eco
Fan Operation REV(Min/Max) setting at Eco
(rpm)
Initial
Normal
Ceiling
L1
L2
43
43
43
43
60
60
60
60
48
48
48
48
100
100
100
100
100
100
100
100
43
43
43
43
61
61
61
61
48
48
48
48
100
100
100
100
100
100
100
100
43
43
43
43
62
62
62
62
48
48
48
48
100
100
100
100
100
100
100
100
10
11
13
11
13
30
15
15
15
15
Normal
Ceiling
L1
L2
26
26
26
26
35
35
35
35
2775
2775
2775
2775
2975
2975
2975
2975
1800
1800
1800
1800
2555
2555
2555
2555
4700
4700
5900
5900
4800
4800
6100
6100
3120
3120
3120
3120
5865
5865
5865
5865
26
26
26
26
35
35
35
35
2495
2495
2495
2495
2795
2795
2795
2795
1625
1625
1625
1625
2245
2245
2245
2245
3650
3650
4850
4850
3725
3725
5000
5000
2605
2605
2605
2605
5275
5275
5275
5275
26
26
26
26
35
35
35
35
2210
2210
2210
2210
2610
2610
2610
2610
1450
1450
1450
1450
1935
1935
1935
1935
2600
2600
3800
3800
2650
2650
3900
3900
2090
2090
2090
2090
4685
4685
4685
4685
-73-
Range
Note
30-100
30-100
20°
160°
30-100
L1
0-100
Normal
Ceiling
0-100
L2
200°
340°
30-100
(-160°)
(-20°)
30-100
Slant
Off
L1
30-100
Ceiling
Off
Normal
Up
On
Ceiling
Up
0-100
Definition of Slant
0-100
Off
-20° ~ 20°
L1
20° ~ 160°
30-100
L2
-20° ~ -160°
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-40
0-40
0-40
0-40
0-40
20-100
20-100
0000-9990
0000-9990
0000-9990
20°
160°
L1
0000-9990
0000-9990
Normal
Ceiling
0000-9990
0000-9990
0000-9990
L2
200°
340°
20-100
(-20°)
(-160°)
20-100
0000-9990
Slant
0000-9990
Off
L1
Ceiling
0000-9990
Off
Normal
Up
On
Ceiling
Up
0000-9990
0000-9990
Definition of Slant
Off
-20° ~ 20°
0000-9990
L1
20° ~ 160°
0000-9990
L2
-20° ~ -160°
0000-9990
20-100
20-100
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
L2
Down
Down
L2
Down
Down