Sanyo PLC-XT35 Service Manual page 74

Chassis no. kp3-xt3500, kp3-xt35l00
Hide thumbs Also See for PLC-XT35:
Table of Contents

Advertisement

Electrical Adjustment
Group/
Item Name
Item
Group 255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
3 Fan4 Initial Pulse
4
5
6
7
8 Cooling Time
9
10 Temp Error Cooling Time
11 OnStart Cooling Start Threshold
12 After shutdown cooling
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage
1 Lamp Vol Threshold
2 Fan1 Speed Gain
3 Fan2 Speed Gain
4 Fan3 Speed Gain
5 Fan4 Speed Gain
Group 257 Fan Dimmer Setting
0 Dimmer Average Check Period
1 Dimmer Average
2 Last Voltage Difference
3 Voltate Difference Goal
Group 258 * Not used
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration
1 Loop Count
2 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START
1 OFFSET AREA V START
2 GAIN AREA H START
3 GAIN AREA V START
4 Image AREA H WIDTH
5 Image AREA V HIGHT
6 OFFSET target
7 OFFSET torelance
8 GAIN target
9 GAIN torelance
Group 263 Auto Calibration (CVBS/SVIDEO) CXA3815
0 Y Image Area Start X
1 Y Image Area Start Y
6 Image Area H Width
7 Image Area V Hight
8 Y Target Level
11 Gain Tolerance
Group 265 Auto Calibration (YCbCr) CXA3815
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
Function
Fan Start Voltage (0.1V)
Cooling Time (x30sec)
1:30sec 3:90sec 15:450sec
Cooling Time at Temp Error (x30sec)
1:30sec 3:90sec 15:450sec
Cooling After Shut Down (0:No 1:Yes)
Current Lamp Voltage (0.1V)(Read only)
Threshold to judge Lamp Voltage Down ( V×
10)
Additional Fan Speed of Min at Lamp Voltage
Down (rpm)
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:6sec, 90sec...10:300sec)
Dimmer Avarage Value (Read only)
Maximum Execution Times (OFFSET->GAIN)
Result of Auto-Calibration (Last Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start Position
Black Level Acquiring Area V-Start Position
White Level Acquiring Area H-Start Position
White Level Acquiring Area V-Start Position
Black/White Level Acquiring Area
Black/White Level Acquiring Area Height
Target Value of Black Level Adj.
Torelance of Black Level Adj.
Target Value of White Level Adj.
Torelance of White Level Adj.
Y Acquiring Area H-Start Position
Y Acquiring Area V-Start Position
Image Level Acquiring Area
Image Level Acquiring Area Height
Target Value of Y Level Adj.
Torelance of Level Adj.
Y
Initial
55
65
35
700
3
3
38
1
-
60
300
300
300
300
1
-
-
-
0
3
0
3
1
975
500
25
500
13
9
3
1
238
1
25
200
13
9
200
1
25
500
-74-
Range
Note
0-255
0-255
0-255
0-4095
* Not used
* Not used
* Not used
* Not used
1-15
* Not used
1-15
0-100
0-1
0-255
30-90
0-1500
0-1500
0-1500
0-1500
0-10
Executes Auto-Calibration when changiing
0 - 1
the Value (PC White 100%)
* Signal auto calibration
1 - 30
0 / 1 / 9
0: OK, 1: Adjusting,9: Error * ReadOnly
1 - 20
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 127
1 - 127
0 - 255
1 - 255
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 1000
0 - 1000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xt35l