Electronic Control System
W W a a l l l l O O v v e e n n s s
RTD Testing
First access Diagnostic Mode. Once in Diagnostic Mode, the RTD temperature as read by the Oven Controller is
shown in the corresponding display.
NOTE: Diagnostic Mode will end 2 minutes after last key stroke or when the CLEAR key is pressed.
Probe Testing
First access Diagnostic Mode. Once in Diagnostic Mode, the Probe temperature as read by the Oven Controller is
shown in the Stop Cook digits in the corresponding display. If the Probe has not been inserted, "0" will be shown as
the Probe temperature. If the Probe has not been completely inserted creating a short circuit of the Probe, "998" will
be shown as the Probe temperature.
NOTE: Diagnostic Mode will end 2 minutes after last key stroke or when the CLEAR key is pressed.
3-23