2.8
System Data Clear
Notes
After storing or changing the system programming data, you can
clear the programming data stored in the system. The system will
restart with the default settings.
1. Slide the system clear switch to "CLEAR."
2. Press the Reset button with a pointed tool.
3. Return the system clear switch to "NORMAL" while the power
indicator is flashing (approximately within 10 seconds).
• After pressing the Reset button, return the system clear switch to
"NORMAL" at step 3 while the power indicator is flashing
(approximately within 10 seconds). Otherwise, the system is not
cleared.
• When System Connection is executed, the system will not accept
incoming outside calls for about 4 minutes after returning the system
clear switch to "NORMAL." The system needs time to establish the
LCR data.
Installation