Sensor Watch Zones; Keypad Sounder On Alarm Zones; Auto Bypass Re-Entry Zones; Enable No Eolr Zones - NAPCO Gemini GEM-P1632 Programming Instructions Manual

Control panel/communicator with keypads
Table of Contents

Advertisement

15
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
16
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
17
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
18
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Press YES or NO)
19
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Press YES or NO)
20
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Press YES or NO)
21
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Press YES or NO)
L
NAPCO Security Systems
Sensor Watch Zones (New Program Only)
Enter the zone numbers of zones to be Sensor Watch zones.
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.
Keypad Sounder On Alarm Zones (New Program Only)
Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones (New Program Only) (Not evaluated by UL)
Enter the zone numbers of zones to be Auto Bypass Re-entry zones.
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back
into the system (armed) when the zone is subsequently closed.
Enable No EOLR Zones (New Program Only)
Press the NEXT/YES button to program all zones except 24 Hr & fire zones for No End Of Line
Resistor. Press the PRIOR/NO button to continue.
Do not program this feature for UL Installations.

Enable Telco Line Fault Test?

Press the NEXT/YES button to enable Telco Line Fault Test.
Press the PRIOR/NO button to continue.
NOTE: There is a preset 60 second Telco Line Fault Test Delay.

Enable Burg Output Chirp on KeyFob?

Press the NEXT/YES button to enable Burg Output Chirp on KeyFob Arm / Disarm.
Press the PRIOR/NO button to continue.
NOTE: The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm.
Enable SIA CP-01?
Press the NEXT/YES button to enable.
Press the PRIOR/NO button to continue.
The SIA CP-01 Features are designed to reduce the incidence of false alarms. NOTE: Do not
enable unless reporting, otherwise system trouble Fail to Communicate may occur.
X
GEM-P1632 Programming Instructions
!
Page 15