Direct Address Programming Example - NAPCO Gemini GEM-P1632 Programming Instructions Manual

Control panel/communicator with keypads
Table of Contents

Advertisement

!
Page 22
The displays shown on the previous page will appear after a brief delay.
B. GEM-K3DGTL/GEM-RP3DGTL Keypads
!
Use the the
button to toggle the cursor between the 4-digit address field and the data entry locations.
A
To access Direct Address Program
!
Mode, press C in the Easy
Enter the address directly using the number buttons.
Menu Mode.
!
The contents of the address will be read automatically, and the cursor will advance to the data field. Enter the
required data directly using the number buttons.
1. Press R.
J
!
Press
to save the contents of each address.
2. Enter the 4 digit Address location
directly using number buttons
EXIT DIRECT ADDRESS PROGRAM MODE: When done, press the
PROGRAMMING OVERVIEW
(0-9).
operation. The panel is now programmed with your program.
The Keypad Programming Worksheets in the back are provided as an address-programming reference to help the
3. Enter the 2 digit data directly
installer modify his custom default program or to make minor field alterations to an existing panel program. It is
using number buttons (0-9).
recommended that the panel be uploaded to Napco's Quickloader software following any keypad programming and that
U
4. Press
to save.
the PCD3000's error-check feature be utilized to reduce the possibility of programming omissions or conflicts.
Note: Most of the addresses shown comprise two data entry locations, left and right digits. Program the left digits on the
To exit, press C.
left data-display segment, and the right digit on the right segment. For those addresses having only one programmable
nibble, program the right segment only; the left segment should display a blank (•).
Keep the Keypad Programming Worksheets on file for future reference.
General Programming Steps
!
1. Contact the central station to ascertain receiver format, data format, event codes, subscriber numbers and
NOTE: "A" =
G 0
telephone number(s).
"F" =
. Press
G 5
!
2. Select the desired features by circling
Worksheets for guidance in selecting the "data" (1,2,4,8) to be entered into those boxes.
Example: GEM-RP2ASe2 / GEM-RP3DGTL / GEM-RP4RFC--Direct Address Programming
!
3. Program the data entered in the boxes on the worksheets into the respective addresses. The display will show the
Program Zones 6, 7 and 8 as Exit/Entry Follower Zones.
entry numerically, but will display "0" for the number 10, and letters "B", "C", "D", "E", and "F" for the numbers 11
through 15, respectively. To program a 10, press
DETERMINE THE DATA ENTRIES
through
, respectively.
G 5
!
1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5
NOTE: See the Direct Address Programming Example on the following page.
through 8 are located at address 0506, left digit. Circle
!
2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, "14" (E) is entered as press
. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as
G4
a blank (•).
ZONE OPTION
EXIT/ENTRY FOLLOWER
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code (Address 0500), then press
2. Answer NO (
F
NOTE: If you pass "ACTIVATE PROGRAM", scroll backward using
3. Press
to enter the Address Program Mode. Address "0000" will display.
C
4. Press
0506
advance to the data field.
5. Press
G 4
U
6. Press
to save. Address 0506 is now programmed with "E •".
7. Enter another 4-digit address to continue programming or press
X
GEM-P1632 Programming Instructions
GEMINI
COMPUTERIZED SECURITY SYSTEM
; "B" =
; "C" =
G 1
for a zero or to clear.
0
"
the respective "address" boxes. Refer to the Programming Options and
G
ZONES
LEFT DATA VALUES
"
)
SUM = 14 (CIRCLE
ZN08
ZN07
ZN06
ZN05
$
#
"
) to all questions until "ACTIVATE PROGRAM Y/N" is displayed; then press the NEXT/YES button.
to access Address 0506. The data for both digits will display and the cursor will
to enter an "E" in the left digit and press
SYSTEM ARMED
3C
01/01/97 12:00AM
INT ERIOR
BYPASS
FIRE/T BL
C
A
1 2
3
B
4
5 6
C
7 8 9 0
DATA ENTRY SELECTIONS
(BINARY VALUE CIRCLED)
8
4
2
8
4
2
"
8
4
; "D" =
G 2
G 3
"
8
4
#
8
2
#
8
2
#
"
8
. To program 11 through 15, press
0
#
"
8
$
4
2
"
the data values for Zones 5–8.
$
4
2
$
"
4
$
"
4
$
#
2
$
#
2
ADDRESS 0506
$
#
"
L
ADDR
R
$
#
"
E
BLANK (•)
1
0506
Table 1. Determining data entry for a location (each
"
"nibble"). Numbers in parentheses indicate data for
ENTER DATA
selected
zones
R
Worksheets that follow.)
.
B
to enter a blank (•) in the right digit.
0
to exit and resume normal keypad operation.
C
Flashing
ENT A1
SYS T BL
CHIME
button to exit and resume normal keypad
NEXT/YES
E
D
PRIOR/NO
F
AREA
G
ENTRY
PRESS
"
N
TOTAL
0
1
blank
R
!
1
1
1
2
2
; "E" =
G 4
!
3
3
4
1
4
!
5
5
6
1
6
!
G
7
7
8
1
8
!
9
9
G 0
1
10
!
G 1
11
1
12
G 2
!
ZONES
G 3
13
RIGHT DATA VALUES
"
G 4
1
14
)
SUM = 0 (CIRCLE
ZN04
ZN03
ZN02
ZN01
!
G 5
15
8
4
2
1
or
features.
(See
.
L
NAPCO Security Systems
Press here to
Select NEXT/
PRIOR address
KEYPAD
DISPLAYS
1
2
;
3
4
5
6
1
7
8
9
0
B
C
D
E
F
Programming

Advertisement

Table of Contents
loading