ZONE OPTI ON S - ZONE S 17 T O 32 (AD DRESS 0601-0705)
ZONE OPTIONS
ZN32 ZN31 ZN30 ZN29
%
$
Priority
Priority with Bypass
Auto-Bypass
%
Selective Bypass
$
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
%
Alarm Output
$
$ Pulsed Alarm Output
PGM1 Output
PGM2 Output
$ Entry/Exit 1
Entry/Exit 2
$ Exit/Entry Follower
&
$
Auto Reset
&
Swinger Shutdown
$
$ Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
$ Alarm Telco 1
Alarm Restore 1
Trouble Telco 1
Trouble Restore 1
Alarm Telco 3
Alarm Restore 3
Trouble Telco 3
Trouble Restore 3
No EOL Resistor
Trouble on Open
Trouble on Short
$ Zone Area 1
Zone Area 2
Interior (Stay) Bypass
Keypad Sounder on Alarm
$ Fire (C)
Fire Alarm Verification
(C)
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Sensor Watch
RESERVED
Chime 2
$
When the Easy Program Menu is used, these features are enabled by default.
%
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
&
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
!
1
NOTES:
(A) 50ms Loop Response only available for zones 1-8.
(B) 2-wire Smoke Detectors only available for zones 7 & 8.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown and Zone Area 1 are enabled for the total number of zones entered in "# OF ZONES IN AREA1 ENTER # ZONES".
Alarm Telco 1 is enabled for the zone number(s) entered in "REPORT ALL ZONES TO CENTRAL ZONES? Y/N".
Entry/Exit 1 and Chime are enabled for the zone number(s) entered in "ENTRY/EXIT ZONES ENTER ZONE #".
Exit/Entry Follower and Interior Bypass are enabled for the zone number(s) entered in "INTERIOR ZONES ENTER ZONE #".
Pulse Alarm Output is enabled for the zone number(s) entered in "FIRE ZONES ENTER ZONE #" or "2-WIRE FIRE ZNS ENTER ZONE #".
Fire is enabled for the zone number(s) entered in "FIRE ZONES ENTER ZONE #".
2-Wire Smoke Detector is enabled for the zone number(s) entered in "2-WIRE FIRE ZNS ENTER ZONE #".
L
NAPCO Security Systems
ZONES 29-32
LEFT DATA VALUES
ADDRESS
"
)
(CIRCLE
L ADDR R
8
4
2
1
0656
8
4
2
1
0657
8
4
2
1
0658
8
4
2
1
0659
8
4
2
1
0660
8
4
2
1
0661
8
4
2
1
0662
8
4
2
1
0663
8
4
2
1
0664
8
4
2
1
0665
8
4
2
1
0666
8
4
2
1
0667
8
4
2
1
0668
8
4
2
1
0669
8
4
2
1
0670
8
4
2
1
0671
8
4
2
1
0672
8
4
2
1
0673
8
4
2
1
0674
8
4
2
1
0675
8
4
2
1
0676
8
4
2
1
0677
8
4
2
1
0678
8
4
2
1
0679
8
4
2
1
0680
8
4
2
1
0681
8
4
2
1
0682
8
4
2
1
0683
8
4
2
1
0684
8
4
2
1
0685
8
4
2
1
0686
8
4
2
1
0687
8
4
2
1
0688
8
4
2
1
0689
8
4
2
1
0690
8
4
2
1
0691
8
4
2
1
0692
8
4
2
1
0693
8
4
2
1
0694
8
4
2
1
0696
8
4
2
1
0697
8
4
2
1
0699
8
4
2
1
0700
8
4
2
1
0701
8
4
2
1
0702
8
4
2
1
0703
8
4
2
1
0704
8
4
2
1
0705
!
!
!
2
4
ZONES 25-28
ZONES 21-24
RIGHT DATA VALUES
LEFT DATA VALUES
"
)
(CIRCLE
(CIRCLE
ZN28 ZN27 ZN26 ZN25 ZN24 ZN23 ZN22 ZN21
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
!
!
4
2
(Address Location 0530 can only be programmed as "blank (•) blank
(•)", "4 blank (•)", "8 blank (•)" or "C blank (•)".
X
GEM-P1632 Programming Instructions
Page 37
ZONES 17-20
ADDRESS
RIGHT DATA VALUES
"
)
(CIRCLE
L
ADDR R
ZN20 ZN19 ZN18 ZN17
2
1
0601
8
2
1
0602
8
2
1
0603
8
2
1
0604
8
2
1
0605
8
2
1
0606
8
2
1
0607
8
2
1
0608
8
2
1
0609
8
2
1
0610
8
2
1
0611
8
2
1
0612
8
2
1
0613
8
2
1
0614
8
2
1
0615
8
2
1
0616
8
2
1
0617
8
2
1
0618
8
2
1
0619
8
2
1
0620
8
2
1
0621
8
2
1
0622
8
2
1
0623
8
2
1
0624
8
2
1
0625
8
2
1
0626
8
2
1
0627
8
2
1
0628
8
2
1
0629
8
2
1
0630
8
2
1
0631
8
2
1
0632
8
2
1
0633
8
2
1
0634
8
2
1
0635
8
2
1
0636
8
2
1
0637
8
2
1
0638
8
2
1
0639
8
2
1
0641
8
2
1
0642
8
2
1
0644
8
2
1
0645
8
2
1
0646
8
2
1
0647
8
2
1
0648
8
2
1
0649
8
2
1
0650
8
!
!
2
4
4
!
"
)
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
!
2