C
LEARANCE TO
Appliance
Top............................. 0 mm (0")
Bottom....................... 0 mm (0")
Side............................ 0 mm (0")
Back........................... 0 mm (0")
Venting
Concentric sections of DV Vent
Top, bottom & sides .. 25 mm (1")
M
The height that a combustible mantel is tted above the re-
place is dependent on the depth of the mantel. This also applies
to the distance between the mantel leg (if tted) and the
replace.
For the correct mounting height and widths refer to Fig. 2 and
the following Mantel Charts.
The tting of a bay window trim kit does not effect the
distances and reference points referred to in the diagram and
chart.
Non-combustible mantels and legs may be installed at any
height and width around the appliance.
When using paint or lacquer to nish the mantel, such paint or
lacquer must be heat resistant to prevent discolouration.
V
W
X
Y
Z
A
B
C
D
E
Top
Louvre
Assembly
10002555/0
C
OMBUSTIBLES
ANTELS
Fireplace
Ref.
V
W
X
Y
Z
Mantel Leg Dimensions (Minimum Width
Ref. Mantel Leg Depth Distance From Edge of Glass
A
B
C
D
E
A Hearth is not mandatory but it is recommended for aesthetic
purpose. We recommend a non-combustible hearth which
projects out 12" (305 mm) or more from the front of the
replace.
Cold climate Installation Recommendation:
1. Choose the unit location.
2. Place the unit into position and secure it to the oor with
1.5" (38 mm) screws, or nails. The holes to secure the
unit to the oor are located just behind the access door
grille on the left and right side of the unit.
3. Frame in the replace with a header across the top. It is
important to allow for the nished wall face when setting
the depth of the frame.
4. Attach the replace to the frame using the adjustable
frame drywall strips (located behind the access door for
shipping). Preset the depth to suit the facing material of
the wall. The strips are adjustable to 1/2"(13 mm), 5/8"
(16 mm) or 3/4" (19 mm), Fig. 3 & 4.
5. Screw through the slotted holes in the drywall strip and
into the pre-drilled holes in the replace side. Measure
from the face of the replace to the face of the drywall
strip to conrm the nal depth.
Fig. 2
-5-
Vermont Castings, Majestic Products.
Mantel Shelf Chart (Minimum Height)
Mantel Depth
Ref.
10" (254 mm)
A
8" (203 mm)
B
6" (152 mm)
C
4" (101 mm)
D
2" (50 mm)
E
10" (254 mm)
8" (203) mm)
6" (152 mm)
4" (101 mm)
2" (51 mm)
H
EARTH
When installing this unit against a non-insu-
lated exterior wall or chase, it is mandatory that
the outer walls be insulated to conform to appli-
cable insulation codes.
F
F
RAMING AND
Mantel Height
12" (305 mm)
10" (254 mm)
8" (203 mm)
6" (152 mm)
4" (101 mm)
10" (254 mm)
8" (203 mm)
6" (152 mm)
4" (101 mm)
2" (51 mm)
INISHING
33/36/39/43 BDVT