Mitsubishi SRK208HENF-L User Manual page 9

Wall mounted type room air conditioner
Table of Contents

Advertisement

Model SRK561HENF-L (Indoor unit)
SRC561HENF-L (Outdoor unit)
Item
Cooling capacity
(1)
Heating capacity
(1)
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Noise level
(5)
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(4)
Refrigerant
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
(Cooling)
(Heating)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) The operation data are applied to the 220V or 240V districts respectively
(3) Limitation of Voltage application
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant per
meter.)
(5) Expressed in sound pressure level.
Model
W
W
kW
A
kW
A
A
dB(A)
Cooling: 45/45
mm
kg
kW
kg
R
W
CMM
ECONO (Orange), HI POWER (Green)
mm(in)
Item
Indoor air temperature
DB
27ºC
20ºC
Minimum: 198V Maximum: 264V
SRK561HENF–L
1 Phase, 220/240V, 50Hz
Heating: 46/46
275‚790‚189
Ivory white
9
Louver fins & bare tubing
Capillary tubes
0.7 (BARREL FREEZE 32SAM)
Tangential fan x 1
23
12/12
13/13
Polypropylene net (washable) x 2
Wireless–Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow),
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Flare connecting
Liquid line: 0.4m
Gas line: 0.35m
Necessary (Both sides)
Connectable
2.5m (3 cores with Earth)
1.5mm
2
x 5 cores (With Earth)
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
SRC561HENF–L
5000/5000
6200/6300
2.08/2.18
10.2/9.53
2.02/2.15
10.5/9.95
44/48
2.40/2.29
Cooling: 53/54 Heating: 54/56
615‚850‚290 + 30
Polar white
53
RM5526GNE4 (Rotary type) x 1
1.9
Line starting
R22 1.35
MC control
Propeller fan x 1
40
34/34
34/34
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
WB
24ºC
6ºC
Standards
JIS C9612, ISO-T1
JIS C9612, ISO-T1
1-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents