Mitsubishi SRK208HENF-L User Manual page 50

Wall mounted type room air conditioner
Table of Contents

Advertisement

Model SRK408HENF-L3
Power source
1 Phase 220/240V 50Hz
Y/GN
BL
BR
Tr
CNC
CNB
BR
CFI
1
WH
5
RD
3
FM
I
Printed circuit board
LM
Color symbol
BK
Black
BL
Blue
BR
Brown
RD
Red
OR
Orange
WH
White
Y/GN
Yellow/Green
Meaning of marks
Symbol
Cc
Capacitor for CM
CF
Capacitor for FM
I
CF
Capacitor for FMo
O
CM
Compressor motor
F
Fuse
FM
Fan motor (Indoor unit)
I
FM
Fan motor (Outdoor unit)
O
LM
Louver motor
PC
Photo coupler
Table of relay operations
Operation
Relay
Control
symbol
part
52X
20S
4
52X
5
FM
O
52X
6
52C
CM
Notes
(1)
; denotes magnetized relay
(2) Th
is room temperature thermistor. Th
1
(for details, refer to pages 19,20,22)
(3) Preset values:
23DH (defroster stop thermostat): opens at over 14˚C
63H (overload protection high pressure switch during heating): closes at 2.02(20.5) / opens at 2.41(24.5) [MPa(kgf/cm
1-50
Indoor unit
Sh1
52C3
52C4 20S 23D
52C
PC
F
250V
52X
3.15A
4
ZNR
52C
52X
4
Parts name
I
Cooling
Heating
Defrost
×
: denotes demagnetized relay
(the heat exchanger thermistor) is the hot start, hot keep, and frost prevention thermistor.
2
Y/GN
T2
T1
BK
1
1
BK
BK
WH
2
2
WH
OR
3
3
BL
BK
RD
4
4
RD
BK
Th1
Th2
Wireless
R-Amp
Display
Symbol
Th
Thermistor
1,2
Tr
Transformer
ZNR
Varistor
20S
4 way valve, coil
51C
Motor protector for CM
52C
Magnetic conductor for CM
52X
Auxiliary relay
4,5,6
63H
High pressure switch
23DH
Defrost thermostat
Outdoor unit
63H
RD
6
52X
5
4
2
2
52X
6
6
BK
7
OR
BK
FMo
20S
52X
5
8
7
CFo
52X
6
8
Sh2
Parts name
2
)]
Sh1
3
23D
51C
2
H
1
C
CM
S
R
Cc

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents