SRC328HENF-L2 (Outdoor unit)
Item
(1)
Cooling capacity
(1)
Heating capacity
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Noise level
(5)
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(4)
Refrigerant
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) The operation data are applied to the 220V or 240V districts respectively
(3) Limitation of Voltage application
Minimum: 198V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant per meter.
(5) Expressed in sound pressure level.
1-6
Model
W
W
kW
A
kW
A
A
dB(A)
mm
kg
kW
kg
R
W
(Cooling)
CMM
(Heating)
mm(in)
Item
Indoor air temperature
DB
27ºC
20ºC
Maximum: 264V
SRK328HENF–L2
1 Phase, 220/240V, 50Hz
Cooling: 40/42 Heating: 41/43
275 x 790 x 174
Ivory white
8
Louver fins & bare tubing
0.6 (BARREL FREEZE 32SAM)
Tangential fan x 1
16
8.5/8.5
9.5/9.5
Polypropylene net (washable) x 2
Wireless–Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow)
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Flare connecting
Liquid line: 0.4m
Gas line
: 0.35m
Necessary (Both sides)
2.5m (3 cores with Earth)
1.5mm
2
x 5 cores (Including earth cable)
Terminal block (Screw fixing type)
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
SRC328HENF–L2
3000/3000
3800/3800
1.39/1.49
6.9/6.9
1.19/1.32
6.1/6.1
33.6/36.6
2.16/2.01
Cooling: 44/46 Heating: 45/47
542 x 795 x 255
Polar white
37
RM5517GNE2 (Rotary type) x 1
1.3
Line starting
Capillary tubes
R22 0.74
MC control
Propeller fan x 1
15
24/24.5
24/24.5
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Connectable
Mounting kit
WB
24ºC
6ºC
Standards
JIS C9612, ISO-T1
JIS C9612, ISO-T1