Specifications - Mitsubishi SRK208HENF-L User Manual

Wall mounted type room air conditioner
Table of Contents

Advertisement

1.2
SELECTION DATA

1.2.1 Specifications

Model SRK25GZ-L1 (Indoor unit)
SRC25GZ-L1 (Outdoor unit)
Item
Cooling capacity
(1)
Heating capacity
(1)
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Noise level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(4)
Refrigerant oil
Deice control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Size × Core number
Connection wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) The values for performance and power consumption shown in brackes [~] indicate the range from minimum to maximum.
(3) The operation data are applied to the 220/240V districts respectively.
(4) Limitation of Voltage application
(5) The refrigerant quantity to be charged includes the refrigerant in 5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer,
(When it is 5 to 15 m, add 20 g refrigerant per meter.)
Model
W
W
kW
A
kW
A
A
dB (A)
mm
kg
kW
kg
R
W
(Cooling)
CMM
(Heating)
Polypropylene net (washable) × 2
Compressor: Overheat protection, heating overload protection (High pressure control), overcurrent pro-
tection, serial signal error protection, indoor fan motor error protection
mm (in)
Item
Indoor air temperature
DB
27ºC
20ºC
Minimum: 198V
SRK25GZ-L1
2500 [900~2900]
3400 [900~4000]
1 Phase, 220/240V, 50Hz
0.96 [0.31~1.22]
4.8
1.17 [0.28~1.35]
5.8
5.8
2.60
Cooling: 38 Heating: 39
250 × 750 × 178
Ivory white
7.5
Louver fins & bare tubing
Capillary tubes
R22 0.64 (Pre-Charged up to the piping length of 5m)
0.35 (BARREL FREEZE 32SAM)
MC control
Tangential fan × 1
18
7.0
7.5
Wireless-Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow)
Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")
Flare connecting
Liquid line: 0.4 m
Gas line : 0.35 m
Necessary (Both sides)
Connectable
2.5 m (3 cores with Earth)
× 4 cores (Including earth cable)
1.5 mm
2
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
Maximum: 264V
SRC25GZ-L1
Cooling: 46 Heating: 46
540 × 645 × 245
Polar white
28
RM5465GA1 (Rotary type) × 1
0.75
Line starting
Propeller fan × 1
20
21
21
Cushion rubber (for compressor)
Standards
WB
24ºC
JIS C9612, ISO-T1
6ºC
JIS C9612, ISO-T1
1-21