Reverse Polarity - Chris-Craft 2014 36 RH Corsair Owner's Manual

Table of Contents

Advertisement

Systems
Shore Power 1 energizes the following circuits:
• Television
• Port Outlets
• Galley Refrigeration
• Microwave/Coffee Maker
• Battery Charger
• Starboard Outlets
• Cooktop
• Water Heater
Shore Power 2 is a dedicated power source for the:
• Air Conditioner
• Cockpit Ice Maker
• Spares for Additional Options
It is not necessary to power both systems at the same time. You may pick and choose which components
to power by selecting the appropriate shore power feed and the associated circuit breakers.
When energizing components it is necessary to also configure the Salon Main Circuit Breaker Panel.
Panel configuration is discussed in

Reverse Polarity

Reverse polarity refers to the reversal of the ungrounded current carrying conductor and the grounded
current carrying conductor. The shore panel automatically senses a reverse polarity and turns on a
"Reverse Polarity Light".
connecting to shore power.
If a reverse polarity occurs:
1. Turn
OFF
the dock main shore power.
2. Verify the shore power cord is correctly seated and locked in place. Perform this step both on the vessel and
at the dock connection.
3. After verifying shore power cord is firmly seated, turn the dock main breaker back on.
4. If the reverse polarity situation still exist, disconnect the power cord and have the dock master check the
wiring at the dock's shore power receptacle.
5. If the wiring at the dock's shore power receptacle is correct, and a reverse polarity situation still exists,
contact a qualified marine technician.
A Reverse Polarity warning is indicated on the Salon Main Circuit Breaker Panel.
3-42
"Salon Main Circuit Breaker Panel" on page
Never
ignore a reverse polarity indication. Ensure polarity is correct when
Shore Power
3-44.