Draining Vented Installations - A.O. Smith ADMR-40 Installation, User And Service Manual

Admr series commercial atmospheric water heater
Table of Contents

Advertisement

6
6.2
Draining vented
installations
Legend
Only applicable numbers are
mentioned.
3. T&P valve (mandatory)
4. stop valve (recommended)
5. non-return valve (mandatory)
6. circulation pump (optional)
7. top to bottom circulation pump
(optional)
9. drain valve
10. manual gas valve (mandatory)
11. service stop valve (mandatory)
12. temperature gauge
(recommended)
14. hot water draw-off points
17. 3-way aeration valve
(recommended)
18. water tank
19. float valve
A. cold water supply
B. hot water supply
C. circulation pipe
D. gas supply
E. overflow pipe
H. overflow pipe
48
Draining
Installation diagram
4
6
5
4
C
9
D
10
Some service activities require the appliance to be drained. The procedure is as
follows:
1. Activate the MENU with
MENU
»OFF
^ ON
È WEEK PROGRAM
2. Position the cursor in front of OFF.
3. Confirm OFF with
4. Switch the appliance OFF (position 0) using the ON/OFF switch on the
control panel.
5. Isolate the water heater from the power supply by putting the isolator
between the appliance and the mains power supply to position 0.
6. Shut off the gas supply (10).
7. Close the stop valve (11) in the hot water pipe.
8. Close the stop valve (4) between the water tank and the cold water inlet (A).
9. Open the drain valve (9).
10. Bleed the appliance (or installation) so that it drains completely.
gis
17
12
B
11
14
3
4
14
7
14
5
C
4
4
.
.
Instruction manual ADMR
H
A
19
E
4
18
IMD-0141 R3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Admr-50Admr-60Admr-115Admr-135Admr-80Admr-90

Table of Contents