3
Legend
1 mounting bracket
2 holes for mounting bracket
3 screws for mounting bracket
4 holes for draught diverter
5 sealing ring
6 screws for draught diverter
7 45° bend
8 chimney pipe
28
Installation
Installing the draught diverter
6
5
4
3. Fit the mounting bracket (1) in such a way that it properly supports the
draught diverter.
4. Drill two holes (2) (3.2 mm bit) for the mounting bracket screws.
5. Screw the mounting bracket tightly to the appliance.
6. Place the draught diverter in the mounting bracket, and mark the centres for
7. Now drill two holes (4) into the top of the appliance (3.2 mm bit).
8. Place the sealing ring (5) on the appliance.
9. Screw the draught diverter tightly in place.
10. Fit:
-
a 45° bend (7) onto the outlet of the draught diverter, followed by:
-
a corrosion-resistant vertical chimney pipe (8) of at least 0.5 metre
length,
-
the remaining flue components.
Note
Use flue components that comply with the regulations
Note
Make sure that the chimney flue discharges into an area approved for this
type of appliance.
is
>0,5 m
8
7
1
(1.3
"Regulations").
Instruction manual ADMR
2
3
IMD-0123 R1