Chimney Flue - A.O. Smith ADMR-40 Installation, User And Service Manual

Admr series commercial atmospheric water heater
Table of Contents

Advertisement

is
3.9

Chimney flue

3.9.1
3.9.2
Legend
A. screws
B. protective cap
C. connector block
Instruction manual ADMR
Warning
The installation should be carried out by an authorised installation engineer,
in compliance with general and local regulations
Introduction
The separately-supplied draught diverter must be used when connecting the
appliance to the chimney flue. The flue gas sensor and flue damper supplied
standard with the appliance must be mounted in the draught diverter. The
electrical parts of the flue damper must also be connected
connection")
inside the control column.
Fitting the draught diverter
The draught diverter can be positioned according to preference. Once it is
positioned, the draught diverter is secured to the top of the appliance using two
screws (6), while it is also supported on a mounting bracket (1) attached to the
side of the appliance. The mounting bracket parts can be found in the plastic
bag attached behind the control column. The assembly procedure is as follows:
Removing the protective cover
1
19
C
1. Loosen the 4 screws (A), and remove the protective cover from the control
column.
The bag with parts, including the mounting bracket (and mounting
components for the flue gas sensor) can now be seen.
2. Take the mounting bracket out of the bag.
(1.3
"Regulations").
12
18
13
30
36
31
(3.10 "Electrical
B
A
IMD-0125 R2
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Admr-50Admr-60Admr-115Admr-135Admr-80Admr-90

Table of Contents