3
3
Required Programming
Required Programming
WALL CONSOLE
/ Overview
MODEL AC SR3
This opener has a serial
FCC ID: B8Q AC SR3
number sticker in which
IC: 2133A-CSD1D
the serial numbers begin
with 10 or higher.
Wall consoles from other manufacturers may not work with openers
of these serial number groups. Use only the wall console provided with
this unit. Each wall console has three buttons.
In your carton you will find one of the following
wall consoles:
Series II Wall Consoles with White Buttons
Indicator Light
Large white button will display Red when wall console is properly
™
wired and Sure-Lock
is OFF. When Sure-Lock
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON, the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE mode will override
STB fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.
NOTE: If opener has a Motion Detector sensor, it will keep powerhead
lights ON as long as motion is detected.
Sure-Lock
™
Button
When Sure-Lock
™
is ON, the powerhead cannot be activated by the
wall console or a remote.
Open/Close Button
Opens and closes door from inside garage.
Indicator Light
–Red indicator backlight is ON.
–When Sure-Lock™ is
ON, the indicator light is OFF
Sure-Lock™ Button
– LOCK disables controls after
door is completely closed.
– UNLOCK allows controls to
work normally.
Independent Light Control Button
Controls door opener lights from inside garage.
8
THE GENIE COMPANY
Residential Door Operator
120V. 60HZ. 5A
S/N:10XXXX XXXXXXX
™
is ON, this light is off
™
OFF.
To powerhead
To powerhead
Series III Wall Consoles with Black Buttons
Indicator Light
Indicator light will display Red when wall console is properly wired and
™
Sure-Lock
is OFF. When Sure-Lock
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON, the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE mode will override STB
fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.
NOTE: If opener has a Motion Detector sensor, it will keep powerhead
lights ON as long as motion is detected.
™
Sure-Lock
Button
™
When Sure-Lock
wall console or a remote.
activate Sure-Lock
Open/Close Button
Opens and closes door from inside garage.
Indicator Light
–Red indicator light is
always ON.
–When Sure-Lock™ is ON,
the indicator light flashes.
Sure-Lock™ Button
– LOCK disables controls
after door is completely
closed.
– UNLOCK allows controls to
™
.
work normally.
Independent Light Control Button
Controls door opener lights from inside garage.
TIP
FROM STBs
W
B / W
STB
™
is ON, the powerhead cannot be activated by the
™
.
™
OFF.
FROM STBs
FROM WALL
CONSOLE
STB
BWC
IWC
To powerhead
To powerhead
W
B / W
FROM WALL
CONSOLE
NOT
NOT
NOT
NOT
USED
USED
USED
USED
BWC
IWC