User Guide: PTP 600 Series
A change of state may generate an SNMP trap and/or SMTP email alert. The loopback
can be disabled from the telecoms configuration sub menu (see
circuits
on page 6-68). See
description of the Telecoms Interface.
TDD Synchronization Alarm
Indicates the current status of the TDD Synchronization (OK, Timing System Failure,
Not Synchronized). Note that a change of state may generate an SNMP trap and/or
SMTP email alert.
Link Mode Optimization Mismatch
The Master and Slave ODUs are configured to use different link mode optimization
methods (one is set to IP and the other TDM).
Fips Operational Mode Alarm
The FIPS operational mode alarm indicates that the unit is FIPS 140-2 capable, but has
not been configured correctly for FIPS 140-2 operation. The FIPS operational mode
alarm values are defined in
Table 7-4 FIPS operational mode alarm values
FIPS mode is not configured
FIPS mode is configured, but not active
Viewing the system status
To display the System Status page, select menu option Status.
The System Status page
the PTP 600 Series from both the wireless and network perspectives.
phn-0896_012v000
Jul 2010
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Configuring telecoms circuits
Table
7-4.
Value
(Figure
7-5) gives the user a detailed view of the operation of
Web-based management
Configuring telecoms
on page
6-68
Meaning
The Security Wizard has not been
completed.
The Security Wizard has been completed,
but the HTTP and Telnet management
interfaces have not been disabled.
for a
7-11