Motorola PTP 600 series User Manual page 370

Ptp 600 series
Hide thumbs Also See for PTP 600 series:
Table of Contents

Advertisement

Task 1: Configure IP and Ethernet interfaces
Attribute
Data Port Auto
Neg
Advertisement
Data Port Auto
Mdix
Data Port Wireless
Down Alert
Local Packet
Filtering
6-10
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Select the data rate that the auto-negotiation mechanism will
advertise as available. Use the same setting for both ends of
the link.
Only select a data rate that is within the capability of
connected network equipment, otherwise loss of service may
occur.
This enables/disables the Auto Medium Dependent Interface
(MDI)/Medium Dependent Interface Crossover (MDIX)
capability. Default is 'Enabled'.
When enabled, this causes the Ethernet link to be dropped
briefly when the wireless link drops. This signals to the
connected network equipment that this link is no longer
available. Connected Ethernet switches can be configured to
forward Ethernet frames on an alternative path identified
using the Spanning Tree Protocol (STP).
'Enabled' means that the management agent learns the
location of end stations from the source addresses in received
management frames. The agent filters transmitted
management frames to ensure that the frame is transmitted
at the Ethernet port, or over the wireless link as appropriate.
If the end station address is unknown, then management
traffic is transmitted at the Ethernet port and over the
wireless link.
'Disabled' means that ALL Ethernet packets received are
transmitted over the wireless link. Local Packet Filtering
should be disabled when external Ethernet switching
hardware or a router is present.
Chapter 6 Configuration and alignment
Meaning
phn-0896_012v000
Jul 2010

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 25600Ptp 49600Ptp 54600Ptp 58600Ptp 59600Ptp 48600

Table of Contents