TEMPERATURE READINGS
RANGE
(50°F.
to
300°F.)
Air temperature readings can be taken
at the lint filter by removing the filter
and placing the accessory temperature
probe (Part NO. 38562) directly in the
lint filter opening. Cycling of the ther-
mostats can actually be observed as
can the temperature of the exhausted
air.
SET UP METER FOR USE AS FOLLOWS:
1. Turn selector knob to TEMP.
2. Insert black negative lead of temper-
ature probe into socket marked -
(negative).
3. Insert red positive lead of temper-
ature probe into socket marked
+
(positive).
4. To calibrate meter, touch black plug
from red positive lead to black nega-
tive lead and turn calibration dial
until needle aligns with CAL.
5. Probe is ready to use -- read blue
scale on meter face marked TEMP.