repaIrs at the unIt
10.10

ReMedy IN cASe OF FAultS

type of malfunctIon
Unit does not start
Unit does not suck in
Unit does not gener-
ate pressure
Poor spray pattern
52
what else?
possIble cause
Motor switch can not
No voltage applied
switched on
Indicating lamp does
not illuminate
400V version
N (neutral) conductor not
connected
Motor switch can not
Unit fuse has triggered
switched on
Indicating lamp illumi-
nates
400V version
Lines missing or inter-
Motor hums
rupted
Air bubbles exit from
Unit is sucking in outside
the return hose
air
Air bubbles do not exit
Inlet valve clogged
at the return hose
Inlet/outlet valve soiled
/ foreign bodies (e.g.
threads) drawn in / worn
Pressure control valve
turned down completely
Unit has sucked in
Air in the oil circuit
Unit reached pres-
Suction filter clogged
sure, but the pressure
collapses, also at the
pressure gage, during
spraying.
Paint cannot be worked in
this state. Due to its prop-
erties the paint clogs the
valves (inlet valve) and the
delivery rate is too low.
Unit reached pressure,
Clogged filter do not let
but the pressure col-
enough paint pass
lapses during spraying.
pressure gauge still
shows high pressure
Tip clogged
Unit does not generate
Relief valve defective
the max. pressure pos-
sible. Paint neverthe-
less exits at the return
hose.
Tip clogged
Incorrect nozzle size
During multiple-gun
Too many guns con-
operation
nected
Super Finish 7000
measures for elImInatIng the malfunctIon
Check voltage supply
Have mains connection checked by a skilled
electrician
Let the motor cool down
Have mains connection checked by a skilled
electrician
Check: Suction system tightened properly?
Inlet valve button leaky? -> Replace wiper and
O-ring (-> refer to Section 10.1)
Press the inlet valve button until the stop is
reached several times by hand
Remove the valves and clean then (-> refer to
Section Pkt.10.2/10.3) / replace worn parts
Turn the pressure control valve to the right un-
til the stop is reached
Bleed the oil circuit in the unit by turning the
pressure control valve completely to the left
(until overturning) and let it run approx. 2 – 3
min. Then turn the pressure control valve to
the right and set the spraying pressure (repeat
process several times, if necessary).
Check the suction filter. If necessary, clean/
replace
Dilute the paint
Check/clean the (high-pressure filter) gun filter
Clean the tip (-> refer to Section 8.4)
Clean or replace the relief valve (-> refer to
Section 10.5)
Clean the tip (-> refer to Section 8.4)
Use different nozzle size
Use fewer guns