dIsplays at the unIt / cleanIng the unIt
8

cleANING tHe uNIt

A clean state is the best method of ensuring operation with-
out problems. After you have finished spraying, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit. The cleaning agent used for cleaning (only
with a flash point above 21 °C) must be suitable for the coat-
ing material used.
Secure the spray gun, refer to the operating manual of
the spray gun.
Remove and clean the tip and tip guard.
1. Open relief valve
valve position
(circulation) and switch on unit
2. Remove suction system from the material container.
The return tube remains over the material container.
3. Immerse the suction system into a container filled with a
suitable cleaning agent
4. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
5. Close relief valve,
valve position
6. Pull the trigger guard of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container
(if appropriate, increase the pressure at the pressure con-
trol valve slowly in order to obtain a higher material flow).
When using multiple-gun operation the trigger guards
must be pulled in succession, in order to increase the
cleaning performance.
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
7. Open relief valve
valve position
(circulation)
8. Pump suitable cleaning agent in the circuit for several
minutes.
Suction system with quick clean (points 9 to 17)
9. Screw the spray gun to the suction tube with both enclo-
sed 22 mm wrenches.
10. Pump a suitable cleaning agent in the circuit for about
1 minute.
11. Pull the trigger guard of the spray gun and lock it with a
clamp.
12. Close relief valve,
valve position
44
(spraying)
(spraying)
13. Clean the suction tube about 3 minutes long.
14. Rinse in the circuit – Open relief valve
valve position
(circulation).
15. Close the spry gun.
16. When cleaning with water repeat the procedure about 3
minutes long with clear water.
17. Remove spray gun from suction tube, close spray gun
connection at suction tube with closure nut.
The cleaning effect is increased by alterna-
tively opening and closing the spray gun.
18. Close relief valve,
valve position
19. Pump the remaining cleaning agent into an open contain-
er until the pump is empty.
20. Switch off the unit
Warm water improves the cleaning effect in
the case of water-dilutable coating materials.
unit with upper hopper
1. Open relief valve
valve position
(circulation) and switch on unit
2. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
3. Close relief valve,
valve position
4. Pull the trigger guard of the spray gun in order to pump
the remaining coating material from the hopper, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).