(1) Communications parameters setting screen
(2) Communications protocol option screen
On the SET OPTICAL screen, select "1: PARAMETER" to call up the
screen shown at left.
Highlighted is the current setting.
Select the desired transmission speed by using the numerical keys or
F7 and F8 keys, and then press the ENT key.
To return to the SET OPTICAL screen, press the C key.
On the SET OPTICAL screen, select "2: PROTOCOL" to call up the
screen shown at left.
Highlighted is the current setting.
[1] SERIAL No.:
Selects whether or not to add serial numbers to
data blocks.
[2] H. PARITY:
Selects whether or not to add a horizontal parity.
[3] LINKUP TIME: Selects the timeout length (in seconds) to be
applied when a link is to be established.
[4] FIELD SPACE: Specifies the treatment of trailing spaces in
fields.
To trim trailing spaces in fields, select Ignore; to
retain them as data, select Data.
Select a desired item by using the numerical keys or F5 and F6 keys.
Then select a desired setting by using the F7 and F8 keys.
To return to the SET OPTICAL screen, press the C key.
If the BHT-Ir protocol or YMODEM has been selected, the serial
number and horizontal parity settings will be ignored.