CHAPTER 13 TROUBLESHOOTING
I. STANDARDS AND ADJUSTMENTS
A.
Mechanical system
1.
Right and left registration adjustment
Check that the front edge image margin of paper fed from each cassette is 2.5
± 2.0mm.
If the standards are off, adjust according to the procedure described below.
1) Remove the cassette from the cassette level that needs adjustment.
2) Loosen the hex screw and move the adjusting plate back and forth. Adjust by lining
up with the 1mm interval scale marks.
13-2
Download Free Service Manual at http://printer1.blogspot.com
Scale
Hex wrench
Figure 13-101
COPYRIGHT © 1999 CANON INC.
(–)
(+)
2.5 ± 2.0mm
1mm
10
CANON GP160 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
0
2
4
6
8