Maintenance; Glass Replacement - Jøtul GF 300 DV Installation And Operation Instructions Manual

Jotul gf 300 dv allagash direct vent gas stove
Table of Contents

Advertisement

Maintenance

Your Jøtul GF 300 DV Allagash and its venting system
should be inspected before use and at least annually by
a qualified service technician.
Use the form on page 30 to keep a maintenance
history of your stove.
IMPORTANT: ALWAYS TURN OFF THE GAS SUPPLY TO THE
FIREPLACE AND UNPLUG THE FORCED AIR BLOWER
BEFORE ANY SERVICE WORK IS PERFORMED ON THE
FIREPLACE.
Annual Cleaning
Vent System
The entire vent system, including the chimney, should be
inspected and cleaned every year. If the intake and
exhaust venting is disassembled for any reason, it
should be reassembled and sealed according to the
manufacturer's instructions provided at the initial
installation.
Burner and Logset
Periodically inspect the Firebox, Valve Compartment,
Convection Airways and optional Blower to BE CERTAIN
THAT THE FLOW OF COMBUSTION AND VENTILATION AIR
IS UNOBSTRUCTED.
The firebox should be vacuumed annually to remove
any surface build up. Use a soft brush attachment and
handle the logs carefully as they are fragile. Be sure to
vacuum or wipe off the pilot assembly and burner
surfaces.
Glass Care
Clean the glass only when necessary. Wipe the surface
with a clean, dampened, soft cloth. Follow with a dry, soft
towel. Take care not to scratch the glass surface.
WARNING:
DO NOT USE ABRASIVE CLEANERS ON THE GLASS. NEVER
CLEAN THE GLASS WHEN IT IS HOT.
Gasket Inspection
It is important that the glass gasket be inspected at least
annually. Examine the ribbon gasket for signs of deterio-
ration and make sure the gasket has a positive seal.
Replace the gasket if necessary. Refer to the replacement
parts list on page 29.
24
FOR REPLACEMENT, USE ONLY JØTUL CERAMIC GLASS
PANEL 220576. DO NOT USE ANY OTHER TYPE OF GLASS
WITH THIS APPLIANCE.
Glass Panel or Gasket Removal
1. Lift the Top Plate off of the stove.
2. Release the two Glass Frame Latches. Pull each latch
handle forward forward to disengage the latch from
the notches in the glass frame.
3. Lift the glass frame all the way up and out of the top
of the stove. Lay this assembly on a flat surface,
protecting the frame from scratches using a blanket or
towel.
3. The glass panel is held in place by four compression
clips. Use a screwdriver or small pliers to pry these up
off the edge of the glass retaining walls. See fig. 40.
4. Remove the old gasket material. See fig. 41.
Glass Clips
Figure 40. Use small pliers to pry the clips off of the glass
panel frame.
Glass Panel or Gasket Replacement
1. Wrap the new gasketing material evenly around the
edge of the glass, peeling back the protective strip to
expose the adhesive as you go. Press the adhesive side
down onto the glass surface. Do not stretch the
gasket.
2. Place the gasketed glass within the frame and press
each of the retainer clips back into place on the
retainer walls.
Figure 41 . Wrap the gasket around the glass panel.