Horizontal Termination
Any horizontal termination must fall within the
shaded portion of the vent window graph illustrated
in figs. 9 or 11. For Snorkel Terminations, see below.
Any horizontal termination except a snorkel termination,
must include:
1)
Minimum rise of 24 in.
2)
Minimum horizontal run of 12 in. when vertical
run is less than 8 ft.
3)
Vertical run no more than 35 ft.
4)
Horizontal run no more than 27 ft.
5)
No more than four 45° or two 90° Elbows
The horizontal termination cap must maintain a 3"
clearance to any overhead combustible projections
2 1/2" or less. It must also maintain 12" clearance from
projections exceeding 2 1/2". See fig. 21.
Wall Cut-out Opening: A minimum 10" X 10" (250 mm x
250 mm) square hole is required for proper pipe clear-
ances through a combustible wall.
DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.
Any horizontal run of vent must be level or have a
1/4 in. rise for every foot of run toward the termina-
tion cap. NEVER ALLOW THE VENTING TO RUN DOWN-
WARD FROM STOVE TO TERMINATION; DOWNWARD
VENT RUNS TRAP HEAT AND CAUSE HIGH TEMPERA-
TURES TO DEVELOP WITHIN THE VENT THAT COULD
START A FIRE.
Install a Vinyl Siding Standoff (Simpson Dura-Vent
#950) between the vent termination and an exterior
wall covered by vinyl siding material to prevent
potential heat damage to the siding.
Do not recess the termination cap into a wall or siding.
Snorkel Terminations
With a 14" Snorkel:
The horizontal run made directly off the rear of the
stove into a 14" snorkel cap should include no more
than a single 12" straight section as shown in fig. 17.
One 45° Elbow may be used for a corner installation as
shown in fig. 19.
With a 36" Snorkel:
The maximum horizontal run may be no more than
6 ft. (182 cm.)
Exhaust Restriction: Under normal circumstances, no
exhaust restriction is recommended. Keep the factory
setting (Position D - fully open).
14
24"
610 mm
Figure 17.
• Minimum vent for horizontal termination.
• 14" Maximum horizontal run directly off rear of stove
with 14" Snorkel termination.
Figure 18. Maximum Horizontal with 36" Snorkel Termination.
45° Elbow
Figure 19. Corner Installation with 14" Snorkel Termination.
12"
305
mm
14"
335 mm
56 1/2"
Max.
1435 mm
12"
vent
25"
pipe or
635 mm
less
36 in.
Snorkel
Max.
(915 mm)
6 ft.
183 cm
Max. 14"
355 mm
See Note F
Fig. 20
12 in.
Straight Pipe
Wall Thimble
and Trim Collar
C L