Heat & Glo TIARAI-BK-C Owner's Manual page 2

Direct vent room heater
Table of Contents

Advertisement

Congratulations on selecting a Heat & Glo gas appliance -
an elegant and clean alternative to wood burning appliances.
The Heat & Glo gas appliance you have selected is designed
to provide the utmost in safety, reliability, and efficiency.
As the owner of a new appliance, you'll want to read and
carefully follow all of the instructions contained in this
Owner's Manual. Pay special attention to all Cautions and
Warnings.
LOCATION: HANG TAG ATTACHED TO REAR OF APPLIANCE
Report No. / Rapport Numéro
3198461
APPROVED FOR CANADA AND USA TO: ANSI Z21.88b-2009 / CSA 2.33b-2009 Vented Gas Fireplace Heaters, and applicable sections
of UL307b Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 "Gas Fired Appliances
for use at High Altitudes." This appliance is manufactured for operation with Natural Gas. For conversion to propane Manufacturer's instructions
must be used. This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required.
FAN TYPE VENTED CIRCULATOR :Optional Blower Kit #GFK-160A. 120 Vac, 60 Hz., 12 Amperes or less.
Route power cord away from unit. Do not route power cord under or over stove.
Thermal Efficiency with blower on* 80.92% NG / 82.44% LP (* With Maximum horizontal length)
CAN/CSA P.4.1-02 Canada Minimum pipe Top Vent: 58.90% NG / 60.09% LP. Rear Vent: 65.04% NG / 66.49% LP
Top Vent:
Input Rate on "HI" (BTU/Hr)
Input Rate on "LO" (BTU/Hr)
Maximum Output (BTU/Hr)**
Main Burner Orifice
Rear Vent:
Input Rate on "HI" (BTU/Hr)
Input Rate on "LO" (BTU/Hr)
Main Burner Orifice
Both:
Minimum Inlet Pressure (Inches W.C.)
Maximum Inlet Pressure (Inches W.C.)
Manifold Pressure on "HI" (Inches W.C.)
AFUE
**Max Venting, Blower On
This appliance equipped for altitudes 0-2000' (0-610m) in USA; and in Canada for altitudes of 0-4500' (0-1370m). In USA for Altitudes above 2000', the vent configuration, orifice or combination of both may need to be
changed. See Owner's Manual for information on making these changes. This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow ANSI
Z223.1/NFPA 54 in USA, or CSA B149.1. in Canada. Install and use only in accordance with manufacturer's installation and operating instructions. NOTE: Have the gas supply line installed in accordance with local building
codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.) / Cet appareil est équipé pour les altitudes
de 0-2000' (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500' (0-1370m). Pour les altitudes au dessus de 2000' aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement
avoir à être changé. Voyez le manuel du propriétaire pour les informations sur ces changements. Cet appareil doit être installé en accord avec les codes locaux, s'il-y-a lieu (et approuvé par dans la République de
M
h
tt )
i
li
ANSI Z223 1/NFPA 54
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. AVERTISSEMENT:
L'opération de cet appareil lorsqu'il n'est pas connecté à un système de ventilation correctement installé et maintenu peut résulter à un empoisonnement d'oxyde de carbone ou même de mort possible.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes.
See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. / Cet appareil doit être utilisé seulement avec le gaz indiqué sur l'étiquette enregistré et
peut être installé dans une maison mobile en place permanente dans les endroits permis par les codes locaux. Voyez le manuel du propriétaire pour des détails supplémentaires. Cet appareil ne doit pas être
converti avec des autres gaz sans l'utilisation d'un ensemble de conversion certifié.
MINIMUM CLEARANCES TO COMBUSTIBLES /ESPACE MINIMUM AUX COMBUSTIBLES
Minimum clearances required from combustible construction for all appliance surfaces.
Espaces minimum exigés de la construction combustible aux surfaces de l'appareil.
A. Side of stove top to side wall
B. Rear of stove to back wall
C. Corner of stove top to side wall
D. Minimum Alcove Height
E. Maximum Alcove Depth
F. Minimum Alcove Width
G. Stove to Ceiling Clearance
H. Top of Pipe to Combustible
Side of Pipe to Combustible
Inside Outside Cornerwall Vent
A, B & C measurements are from stove top, not side / "A, B & C" mesure est du sommet de poêle, pas le côté
HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the appliance must be stable, level, and strong enough to support the
appliance without a tipping hazard. / CHEMINÉE: Un coussinet non-combustible de cheminée n'est pas exigé. Cependant, le plancher en dessous du
poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.
Right and left sides of appliance are determined when facing the front of appliance. / Les côté gauches et droits de l'appareil sont déterninés
lorsque vous êtes en face de l'appareil.
2010
2011
2012
Date of Mfg /
Date du
Manufacturier
Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d'Amérique par des pièces d'origine américaine et pièces importées.
2
Read this manual before installing or operating this appliance.
Please retain this owner's manual for future reference.
Congratulations
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
MODEL / MODÈLE:
TIARA I-C GAS STOVE
VENTED GAS FIREPLACE HEATER
NOT FOR USE WITH SOLID FUEL
FOURNAISE AU GAZ AVEC VENTILATION
NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE
For use with Natural Gas
For use with Propane
Usage Au Gaz Naturel
Usage Au Gaz Propane
0-2000 FT
0-2000FT
30,000
28,500
21,000
19,700
24,276
23,495
.106 (#36 DMS)
.063 (#52 DMS)
26,000
26,000
18,000
19,000
.098 (#40DMS)
.059 (#53DMS)
5"
10"
11"
13"
3.5"
10"
79.15%
80.62%
CSA B149 1 I
t ll
t tili
d
l
ELECTRICAL SUPPLY / FOURNITURE ÉLECTRIQUE: 120 Volts, 60 Hz
8-1/2" (216mm)
Du côté du poêle au côté du mur
1/4" (6mm)
Le contrôle arrière au mur arrière
3/8" (9mm)
Du coin du dessus du poêle au mur de côté
54" (1372mm)
Hauteur minimum du plancher au plafond
36" (914mm)
Profondeur maximum de l'alcove
40" (1016mm)
Largeur minimum de l'alcove
27" (686mm)
Le poêle au dégagement de plafond
1-1/2" (38mm)
Le sommet de tuyau à combustible
1" (25mm)
Le côté de tuyau à combustible
9" (229mm)
À l'intérieur de conduit de mur de coin extérieur
Jan
Feb
Mar
Apr
May
Heat & Glo • TIARA I-C • 7066-100 Rev. D • 12/11
This Owner's Manual should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
Your new Heat & Glo gas appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of gas appliance products!
Serial No / Numéro du
007021
APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: ANSI Z21.88b-2009 / CSA 2.33b-2009 Fournaises au Gaz avec Ventilation, et les sections
applicable de UL 307b Appareils de Chauffage Au Gaz pour les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 "Gas Fired Appliances
for use at High Altitudes". Cet appareil est manufacturé pour l'opération avec le Gaz Naturel. Pour une conversion au gaz propane Manufacturier
instructions doivent être utilisées. Cet appareil peut être utilisé dans une chambre à coucher ou salle de séjour; au Canada, l'installation d'un thermostat
à distance est exigée.
VENTILATEUR CIRCULATOIRE: Le Souifleur Optionel Kit #GFK-160A. 120 Vac, 60 Hz., 12 Amperes ou moins.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessous de l'appareil.
Efficacité thermique* avec ventilateur allumé 80.92% NG / 82.44% LP (* avec longueur horizontale maximum)
CAN/CSA P.4.1-02 Le canada tuyau minimum Top Vent: 58.90% NG / 60.09% LP, Rear Vent: 65.04% NG / 66.49% LP
Puissance Évaluée à "HI" (BTU/Hr) - Évent Supérieur
Puissance Évaluée à "LO" (BTU/Hr)
Puissance Maximum (BTU/Hr**
Orifice du Brûleur Principal
Puissance Évaluée à "HI" (BTU/Hr) - Évents Arrière
Puissance Évaluée à "LO" (BTU/Hr)
Orifice du Brûleur Principal
Pression Minimum de la Valve (pouces W.C.) - Tout Ensemble
Pression Maximum de la Valve (pouces W.C.)
Pression du Collecteur d' Échappement à "HI" (pouces W.C.)
AFUE
**Ventilation Maximum, Ventilateur Allumé
i
t
ti
d'i
t ll ti
t d'
é ti
d
f
t i
Jun
Jul
Aug
Sep
Oct
1445 North HIghway
Colville, WA 99114
www.quadrafire.com
SIDE A
REMARQUE L
d it
d it êt
i
t llé
f
é
SIDE B
F
C
B
A
A
E
C
H
G
G -Alcove
de l'alcôve
D
A
A
90° off top up & out ceiling
clearance 90° du sommet en
haut et hors le degagement
de plafond
Nov
Dec
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER L'ÉTIQUETTE
Serial
Number
Model
Name
Test Lab &
Report No.
t
Mfg Date

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tiarai-br-cTiarai-ces-c