Troubleshooting - RIDGID GP80145SW Owner's Manual

8 gallon portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

PROBLEM
Engine will not start.
Engine lacks power.
Air tank pressure drops when compres-
sor shuts off.
Excessive moisture in discharge air.
Compressor runs continuously.
Air output lower than normal.
CAUSE
On/stop switch is in off position.
No fuel.
Fuel valve is off.
Spark plug faulty, fouled, or improp-
erly gapped.
Choke lever is in RUN position.
Tank is full of air.
Fuel element clogged.
Defective pressure unloader.
Loose connections (fittings, tubing, etc.).
Loose drain valve.
Pressure unloader leaking.
Excessive water in air tanks.
High humidity.
Defective pressure unloader.
Excessive air usage.
Piston rings are worn.
Broken inlet valves.
Connections leaking.
16 – English
SOLUTION
Turn the on/stop switch to ON.
Fill fuel tank.
Turn fuel valve on.
Replace spark plug.
Move choke lever to START position.
Compressor will turn on when tank
pressure drops to cut-in pressure.
Check air filter element. Clean or replace
as needed.
Take compressor to service center.
Check all connections with soap and
water solution and tighten.
Tighten drain valve.
Take compressor to service center.
DANGER:
Do not disassemble pressure
unloader, tank drain valves or safety
relief valve with air in tank — bleed
tanks.
Drain tanks.
Move to area of less humidity; use air
line filter.
Take compressor to service center.
Decrease air usage; compressor not
large enough for tool's requirement.
Replace piston rings; Call customer
service for assistance.
Take compressor to service center.
Tighten connections.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents