Pre-Installation; Features; Packaging List; Ratings - Superior DRI3030TEN Installation And Operation Manual

Direct-vent fireplace insert
Hide thumbs Also See for DRI3030TEN:
Table of Contents

Advertisement

PRE-INSTALLATION

Features

Installation Options
Manufactured (Mobile) Home
Natural Gas Or Propane (LP)
Bedrooms
Remote Control
Electrical
The standard blower motor requires 120 Volts AC for operation. The
fireplace is not dependent on the blower to operate. WARNING - Electrical
Grounding Instructions - This appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle.
Do not cut or remove the grounding prong from this plug.
Electronic Valve
This appliance is equipped with an electronic valve and electronic pilot
ignition system (which can be switched from Intermittent to standing
pilot mode - see Page 19). External electrical 120 Volt power is required
to operate the blower system of this appliance and recommended to oper-
ate the burner system. This appliance is equipped with a battery backup
system in case of a power outage (see Battery Backup on Page 17 for
more information).
Fuel
This appliance comes from the factory equipped to burn natural gas at
a specified elevation. The appliance can be converted to burn LP (liquid
propane) by installing a conversion kit. Only IHP conversion kits can be
used to convert from NG to LP or LP to NG. Contact your IHP dealer
for details.

RATINGS

Max/Min Input BTUh 0-2,000 Feet
(0-610 M)
u
Manifold Pressure (IN. WC)
Min. Inlet Pressure (IN. WC)
Maximum heat output BTUs/hour-
steady state (depending on vent con-
figuration)
v
P4 Efficiency
w
Orifice (DMS) 0-2,000 Feet (0-610 M)
u
Unit factory equipped for 0-2000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
v
The Steady State Efficiency numbers based on maximum vent configuration.
w
Tested to CSA P.4.1-02 "Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 120 VAC, 60 HZ, Less Than 2 Amps
8

Packaging List

Insert Body Packaging List
Decorative Faces - One Required
Surround Kits - One Required
* See detailed dimensions on Page 33.
Surround Kit Contents
Firebox Liner Kits - One Required
DRI3030TEN-40 / DRI2530TEN-40
NATURAL GAS
40,000/28,000
3.5
5.0
83%
67.17%
1/8"
u
1 Insert Body
1 Log Set
1 Bag of Embers
1 Power Cord
1 Fasteners: 6 slotted 1/4" truss screws
6 speed nuts
9 spring clips
3 plastic adhesive wire restraints
1 Installation and Operation Manual
Contemporary Face
Traditional 1-pc. (41"W x 29"H)
Traditional 3-pc. (41"W x 29"H, 48"W x 29"H, 41"W x
33"H or 48"W x 33"H)
1 Top Surround
2 Side Surrounds
3 Black Extruded Trim Pieces
2 Elbowed Trim Fasteners
Tan Brick
Architectural Stone
Red Brick
Zen Garden
DRI3030TEN-33 / DRI2530TEN-33
LP GAS
NATURAL GAS
37,500/26,000
33,000/24,000
10.0
10.5
83%
69.07%
65.55%
#49
LP GAS
33,000/24,000
3.5
10.0
5.0
10.5
83%
83%
67.80%
#36
#51