Idle Current Test - HTC Neon Service Manual

Table of Contents

Advertisement

Doc. Title

Idle current test

Sleep current test
If current consumption is passed at both of idle and sleep mode, it means M/B is
GOOD. If there is any item FAILED at idle or sleep mode, it means M/B is failed,
Model Jig Type
NEON
A
HTC CONFIDENTIAL
HTC Corporation
.
Neon Service Manual
please replace M/B for repair.
Button set up matrix
A
B
C
0
8
0
3. In "main page", Check phone status,
Click "Turn on flight mode"
Set the unit to :
* Flight mode
* Make sure all RF function is off (phone,
BT, Wifi..)
4. Measure Idle mode current. Idle current
value must under 32mA, if over the
criteria, it means M/B failed, please
replace M/B for repair.
5. After idle current checked, Switch OFF
the unit. Unit is turn off and no display.
Sleep current value must under 1.7mA, if
over the criteria, it means M/B failed,
please replace M/B for repair.
Conclusion:
Idle Current <=
D
0
32 mA
Doc. No.
DOC- 00036367
Issued Date
1/12/2007
Revised Date
11/19/2008
Page
54 of 88
Testing Criteria
Sleep Current <=
1.7 mA
SM-TP002-0706
REV.
A06

Advertisement