Component Testing Information
Note: The heater will not turn on more than once in a
wash cycle (no reheating).
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
ATC Control
When ATC cold wash is selected, the Heater turns on if
the water temperature in the tub is below 60 degrees F.
The heater turns off when the water temperature is above
70 degrees F or time has expired for the wash cycle. The
cycle time will not be extended to reach the desired
temperature.
When ATC warm wash is selected, the heater turns on if
the water temperature in the tub is below 95 degrees F.
The heater will turn off when the water temperature is
above 105 degrees F or time has expired for the wash
cycle. The cycle time will not be extended to reach the
desired temperature.
Water flow through dispenser during Wash fill
DRAIN
DRAIN
©2005 Maytag Services
!
WASH
WASH
FILL /
FILL /
(HEATING)
(HEATING)
Rotation of
Rotation of
Spinner
Spinner
16026126 Rev. 0
WARNING
When hot wash is selected, the heater will turn on if the
water temperature in the tub is below 120 degrees F. The
heater turns off when the water temperature is above 130
degrees F. or or time has expired for the wash cycle. The
cycle time will not be extended to reach the desired
temperature.
When the Sanitary Cycle is selected, the heater turns on
if the water temperature in the tub is below 141 degrees
F. The heater turns off when the water temperature is
above 151 degrees F. The wash cycle will be extended to
achieve the temperature of 151 degrees F.