INSTALLATION

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15
minutes.
If any of the original wires as supplied with the
appliance must be replaced, it must be replaced
with CSA type SEW (200
o
C) or its equivalent.
This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However, a
120V A.C. power supply is needed for the fan/
blower operation.
NATURAL GAS
For
36
2) If required, adjusting the primary air to
ensure that the fl ame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.
3) Check for proper draft.

WIRING DIAGRAMS

Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
NOT
Units and Units
Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.
CAUTION:
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
tion.
Equipped with DC Spark Boxes
®
Hampton
H27 Direct Vent Freestanding Gas Stove
CAUTION
Label all wires prior