Optional Wall Thermostat; Back Up Battery; Remote/Receiver Coding; Manual Operation(No Remote) - HAMPTON BAY H15-NG10 Owners & Installation Manual

H15-10 series direct vent gas fireplace
Hide thumbs Also See for H15-NG10:
Table of Contents

Advertisement

OPTIONAL
WALL THERMOSTAT
A wall thermostat may be installed if desired. Con-
nect the wires as per the wiring diagrams. Use
table below to determine the maximum wire length.
Note: Preferable if the thermostat is installed
on an interior wall.
Hampton
offers an optional programmable thermo-
®
stat but any 250-750 millivolt rated non-anticipator
type thermostat that is CSA, ULC or UL approved
may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.

BACK UP BATTERY

In the event of a power outage the unit may be
operated by a back up battery system.
1. Open the right (when facing front of appliance)
access panel by removing 1 screw.
2. Install 4AA batteries into the battery holder.
Note: Remove the batteries when normal opera-
tion is resumed as the heat will drain the bat-
tery power rapidly.

REMOTE/RECEIVER CODING

To code the receiver to the hand held remote,
follow the procedure below.
1. Open the left (when facing front of appliance)
access panel by removing 1 screw.
2. Plug in 120 volt power cord into a grounded
receptacle or install 4 AA batteries into battery
pack and plug into battery terminals located
near the gas valve. Do not use both. Only use
the 4 AA batteries if 120 volt power is not
available.
3. Install 3AAA batteries into handheld remote.
4. Hold down the red button on the receiver until
you hear 3 beeps.
location of red button
installation
5. Hold down the ON/OFF button on the hand
held remote to code the remote to the re-
ceiver–after 4 beeps are heard–handheld is
paired with receiver.
MANUAL OPERATION
(NO REMOTE)
To override the remote - open the left access
panel (if facing unit). Press the red button on
IFC until it beeps 3 times and the amber light
illuminates,within 10 seconds press and hold
the red button again until a beep is heard.
After overriding the remote - the ON/OFF
switch at the front of the unit will control the
unit.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15min. to stabilize.
3) Check for proper draft.
Any alteration to the product that causes soot-
ing or carboning that results in damage to the
exterior facia is not the responsibility of the
manufacturer.
Hampton® H15-10 Direct Vent Freestanding Gas Stove
|
35
CAUTION
|
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H15-lp10