Wall Thermostat; Remote/Receiver Coding; Manual Operation(No Remote); Final Check - HAMPTON BAY H35-10 Owners & Installation Manual

Table of Contents

Advertisement

installation
|
36
G)02-48
Side View
Bracket
The bottom right edge of Log G)02-48 must sit
snugly against the bracket. (Front Log 02-45 has
been removed so that the bracket can be seen.)
13) Test fire to ensure proper light off (make sure
flame flows smoothly from one end of burner
to the other. If there is any flame hesitation,
check that area for any blockage of the burner
port.
B)02-56
C)02-44

WALL THERMOSTAT

A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH" on
the gas valve. Use table below to determine the
maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
Hampton
offers an optional programmable thermo-
®
stat but any 250-750 millivolt rated non-anticipator
type thermostat that is CSA, ULC or UL approved
may be used.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-10 System)
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
36 |
Hampton® H35-10 Direct Vent Freestanding Gas Stove

REMOTE/RECEIVER CODING

To code the receiver to the hand held remote,
follow the procedure below.
1. Open the access panel of the unit.
NOTE: Ensure that the main ON/OFF switch is in
the ON position. (Unit will not function, un-
less it is in ON position.
A)02-43
2. Unscrew the 2 screws (1 on each side) from
the valve cover plate and take it out.
E)02-45
3. Locate the IFC on the front right side of the
unit (when facing the unit) as shown below in
the picture.
4. Plug in 120 volt power cord into q grounded
receptacle or install 4 AA batteries into battery
pack and plug into battery terminals located
near the gas valve. Do not use both. Only
use the 4 AA batteries if 120 volt power is not
present.
5. Install 3 AAA batteries into the handheld
remote.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Access Panel
6. Hold down the red button on the receiver until
you hear 3 beeps, ensuring that unit is pow-
ered.
IFC
location of red button on IFC
7. Press the ON/OFF button on the handheld re-
mote within 10 seconds to code the remote to
the receiver-after 4 beeps are heard-handheld
is paired with receiver.
MANUAL OPERATION
(NO REMOTE)
To override the remote - open thefront access
panel and the valve cover plate. Press the
red button on IFC until it beeps 3 times and
the amber light illuminates,within 10 seconds
press and hold the red button again until a
beep is heard.
After overriding the remote - the ON/OFF
switch at the front of the unit will control the
unit.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that causes soot-
ing or carboning that results in damage to the
exterior facia is not the responsibility of the
manufacturer.

Hide quick links: