Final Check

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.

Wiring Diagrams

If any of the original wires as supplied with the appliance must be replaced, it must be replaced with CSA type SEW (200
This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However, a
120V A.C. power supply is needed for the fan/
blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
(To THTP)
White
(To TH)
Red
Cut here
(OPTIONAL REMOTE)
ON
White
Red
This appliance is equipped with a three pronged (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this plug.
Hampton
®
H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
2) If required, adjusting the primary air to
ensure that the flame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.
3) Check for proper draft.
CAUTION:
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
tion.
DC
SPARKER
Green
Black
Red
White
Red
To Thermocouple IN
Receiver
OFF
Remote
Remote
(To THTP)
(To TH)
Cut here
(OPTIONAL REMOTE)
ON
Remote
WARNING: Electrical Grounding Instructions
Label all wires prior
(120V AC)
Neutral
Live
Gas In
DC
SPARKER
Green
Black
Red
White
Red
To Thermocouple IN
Receiver
OFF
Remote
CAUTION
Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.
C) or its equivalent.
o
Fan
Fan
Black
White
Ground /Green
ON
OFF
Red
Black
Rotary Speed
Fan Thermodisc
Control
(normally open)
Gas In
installation
Green
Ground
Black
(120V AC)
Neutral
Live
B