OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams. Use
table below to determine the maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
Regency
offers an optional programmable
®
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

REMOTE/RECEIVER CODING

To code the receiver to the handheld remote, followt
the procedure below:
1. Open the access panel of the unit and unscrew
the 2 screws from each side of the valve
cover plate.
2. IFC will be in the front left side of the unit
(when facing the unit).
50 Ft.
32 Ft.
3. Plug in 120 volt power cord into a grounded
20 Ft.
receptacle or install 4 AA batteries into battery
pack and plug into battery terminals located
12 Ft.
near the gas valve. Do not use both. Only use
9 Ft.
the 4 AA batteries if 120 volt power is not
present.
4. Install 3 AAA batteries into handheld remote.
5. Hold down the red button on the receiver
untill you hear 3 beeps.
6. Press the ON/OFF button on the hand held
remote to code the remote to the receiver–af-
ter 4 beeps are heard–handheld is paired with
receiver.
MANUAL OPERATION
(NO REMOTE)
To override the remote - open thefront access
panel and the valve cover plate. Press the red
button on IFC until it beeps 3 times and the
amber light illuminates,within 10 seconds press
and hold the red button again until a beep is
heard.
After overriding the remote - the ON/OFF switch
at the front of the unit will control the unit.

FINAL CHECK

Before leaving this unit with the customer, the installer
must ensure that the appliance is firing correctly.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15 min. to stabilize.
3. Check for proper draft.
Any alteration to the product that causes sooting
or carboning that results in damage to the exterior
facia is not the responsibility of the manufacturer.

BACK UP BATTERY

In the event of a power outage the unit may be
operated by a back up battery system.
1. Open the access panel of the unit and un-
screw the 2 screws from each side from the
valve cover plate.
2. Install 4AA batteries into the battery holder.
location of red button
Note: Remove the batteries when normal opera-
tion is resumed as the heat will drain the bat-
tery power rapidly.
Hampton
H27-10 Direct Vent Freestanding Gas Stove
®
installation
CAUTION
|
35
|
35