Fan Operation; Adjusting Flame Height; Final Check; Summary Of Controls - HAMPTON BAY HG35-NG1 Owners & Installation

Direct vent gas fireplace
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

FAN OPERATION

The fan speed can be adjusted using the Control
Panel located at the back of the unit on the top
right hand side.
Pressing and releasing the plus (+) FAN button
will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.
Pressing and releasing the minus (-) FAN button
will be the reverse of the above.
ADJUSTING FLAME
HEIGHT
There are six fl ame settings that can be adjusted
by pressing and releasing the plus (+) and minus
(-) FLAME button.
The FLAME setting button is located on the
control panel in behind the pedestal door.
30

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to
ensure that the fl ame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of the
manufacturer.
SUMMARY OF
CONTROLS
On/Off Button
If the unit is switched off, pressing and releasing
this button once will switch the unit on. The unit
will resume its last settings.
If the unit is switched on, pressing and releasing
this button once will switch the unit off.
Flame:
Increase - If the unit is switched on, pressing
and releasing the fl ame plus (+) button once will
increase the fl ame height to the next available
high setting.
Decrease - If the unit is switched on, pressing
and releasing the fl ame minus (-) button once
will decrease the fl ame height to the next avail-
able low setting.
Fan:
Increase - If the unit is switched on, pressing
and releasing the fan plus (+) button once will
increase the fan speed to the next available
high setting.
Decrease - If the unit is switched on, pressing
and releasing the fan minus (-) button once will
decrease the fan speed to the next available
low setting.

PILOT ADJUSTMENT

Periodically check the pilot fl ames. The correct
fl ame pattern has 3 strong blue fl ames.
One fl owing around the thermocouple, the sec-
ond fl owing across the rear of the burner (it does
not have to be touching the burner) and the third
fl ame fl owing tangent to the spark ignitor.
NOTE: If you have an incorrect fl ame pat-
tern, contact your Regency dealer for further
instructions.
Rear of Burner
Front of Burner
An incorrect fl ame pattern will have small,
probably yellow fl ames, not coming into
proper contact with the rear of the burner or
thermopile.
Rear of Burner
Front of Burner
Hampton HG35-1 Direct Vent Freestanding Gas Stove