Panasonic KX-TDA100 Installation Manual page 66

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

2.2 Installation of the Hybrid IP-PBX
Outside Installation
Surge Protector
CO Line
Terminal
Extn.
SLT
If you install an extension outside of the building, the following precautions are recommended:
a.
Install the extension wire underground.
b.
Use a conduit to protect the wire.
Note
The surge protector for an extension and CS is different from that for a CO line.
Installation of an Earth Rod
Surge Protector
CO Line
Grounding
Wire
(Underground)
66
Installation Manual
(Main Building)
CO Line
Hybrid
IP-PBX
Board
Extn.
Extn.
PT
CS
Hybrid
IP-PBX
Earth Rod
(Another Building)
SLT
Extn.
PT
CS
Surge
Protector
Earth
Extn.: Extension Line