2.7 Connection of Extensions

2.7
Connection of Extensions
2.7.1
Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
* The maximum cabling distance from the Hybrid IP-PBX is the same even when the KX-T7600 series
DPT is the master DPT on the Digital XDP connection.
Notice
The maximum cabling distance may vary depending on the conditions.
112
Installation Manual
Cable
Maximum Distance
26 AWG:
Under 222 m (728 ft)
24 AWG:
Under 347 m (1138 ft)
22 AWG:
Under 500 m (1640 ft)
CAT 5:
Under 347 m (1138 ft)
Cable
Maximum Distance
26 AWG:
Under 500 m (1640 ft)
24 AWG:
Under 720 m (2362 ft)
22 AWG:
Under 830 m (2723 ft)
CAT 5:
Under 720 m (2362 ft)
Cable
Maximum Distance
26 AWG:
Under 140 m (459 ft)
24 AWG:
Under 229 m (751 ft)
22 AWG:
Under 360 m (1181 ft)
CAT 5:
Under 229 m (751 ft)
Cable
Maximum Distance
26 AWG:
Under 698 m (2289 ft)
24 AWG:
Under 1128 m (3700 ft)
22 AWG:
Under 1798 m (5897 ft)
CAT 5:
Under 1128 m (3700 ft)
PT-interface CS
KX-T7600 Series *
Other PT (DPT/APT)
and DSS Console
SLT