Error Code
Error Message
323
IP-GW SDRAM
Failure
324
IP-GW DPRAM
Failure
325
IP-GW LAN Chip
Failure
326
IP-GW Stop
350
IP-unit SDRAM
bit error
351
IP-unit download
data check-sum
error
352
IP-unit DSP
failure
353
IP-PT DSP failure •
355
IP-unit alive check
error
356
IP/TEL-unit
communication
error
357
IP-unit FLASH
access error
358
IP-unit boot error
359
IP-unit DSP
failure (boot
diagnosis)
360
IP-PT SUB-CPU
failure
361
IP-PT DHCP
server no
response
PROBABLE CAUSE
•
Detection of IP-GW SDRAM
error
•
Detection of IP-GW DPRAM
error
•
Detection of IP-GW LAN Chip
failure
•
IP-GW is stopped from a
remote maintenance PC
•
Optional service card
malfunction: IP-EXT
•
Optional service card
malfunction: IP-EXT
IP-PT malfunction
•
Optional service card
malfunction: IP-EXT
•
Optional service card
malfunction: IP-EXT
•
IP-PT malfunction
•
DHCP server is not active
•
Network malfunction
SOLUTION
•
Replace the corresponding optional
service card
•
Replace the corresponding optional
service card
•
Replace the corresponding optional
service card
•
Collect the log data of IP-GW (refer to
the documentation for the IP-GW card)
•
This information is logged when IP-GW
is stopped from a remote maintenance
PC
•
The IP-EXT card will be rebooted
automatically if the error is temporary
•
Replace the corresponding IP-EXT
card if the card is not started up
correctly
•
Replace the corresponding optional
service card
•
The IP-PT will be rebooted
automatically if the error is temporary
•
Replace the corresponding IP-PT if the
IP-PT is not started up correctly
•
The IP-EXT card will be rebooted
automatically if the error is temporary
•
Replace the corresponding IP-EXT
card if the card is not started up
correctly
•
Replace the corresponding optional
service card
•
The IP-PT will be rebooted
automatically if the error is temporary
•
Replace the corresponding IP-PT if the
IP-PT is not started up correctly
•
Consult your network administrator
Installation Manual
4.1 Troubleshooting
181