SAFETY LABEL

This is a copy of the labels that accompany each
E33 Gas Insert. We have printed a copy of the
contents here for your review. The safety label
is located on a plate inside the base of the unit
visible when the bottom louver is opened. Ensure
that the safety label is attached to the unit.
NOTE: FPI units are constantly being
improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
4
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE
Listed: VENTED GAS FIREPLACE HEATER
Tested to: ANSI Z21.88b-2003/
Certified for / Certifiée pour: CANADA AND U.S.A.
REPORT number 303530
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold Pressure
Orifice Size
Minimum Input
Maximum Input
PROPANE GAS FIREPLACE
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold Pressure
Orifice Size
Minimum Input
Maximum Input
VENTED GAS FIREPLACE HEATER
For installation in Solid Fuel Burning Fireplaces. This appliance must be installed in
accordance with local codes, if any. If none, follow the National Fuel Code, ANSI
Z223.1/NFPA 54 or Natural Gas and Propane Installation Codes, CSA B149.1. This
vented gas fireplace heater is not for use with air filters.
For Manufactured Home Installation: This Direct Vent System Appliance must be
installed in accordance with the manufacturer's installation instructions and
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the
current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and
Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in
Canada.
This appliance is only for use with the type of gas indicated on the rating plate. See
owner's manual for details. This appliance is not convertible for use with other gases,
unless a certified kit is used.
WARNING:
This fireplace has been converted for use with a gas fireplace insert only
and cannot be used for burning wood or solid fuels unless all original parts have been
replaced, and the fireplace re-approved by the authority having jurisdiction. For use with
glass doors certified with the appliance only.
Fan Part No. 910-331/P
Electrical Supply: 115 V, 56 WATTS, 60 Hz
NOT FOR USE WITH SOLID FUEL
Minimum Clearances to Combustibles from Insert
Side Walls
*A 8"
Ceiling
B
47"
Min. Mantel Height
C
15"
Max. Mantel Depth
D
3½"
Alcove Width
E
76"
Alcove Depth
F
36"
Non-Combustible Hearth Extension
Hearth Height
G 1-1/4"
Hearth Width
H
45-1/2"
Hearth Depth
I
13"
* Alcove side wall must have a min. of 8"
clearance on one side.
FPI Fireplace Products International Ltd., Delta BC, CANADA
MADE IN CANADA / FABRIQUE AU CANADA
`
298
Serial No. / No de serie
CSA 2.33b-2003,
CAN/CGA-2.17-M91
MODEL E33-NG1
5"
WC
(1.25 kpa)
1.1"
WC
(0.27 kpa)
3.8"
WC
(0.95 kpa)
31
DMS
20,000
Btu/h
(5.86
38,000
Btu/h
(11.13 kW)
INSERT: MODEL E33-LP1
12"
WC
(2.99 kpa)
2.9"
WC
(0.72 kpa)
11"
WC
(2.74 kpa)
5 0
DMS
19,000
Btu/h (5.56 kW)
35,500
Btu/h (10.4 kW)
(203mm)
(1194mm)
(381mm)
(89mm)
(1930mm)
B
(914mm)
D
(32mm)
A
(1156mm)
C
(330mm)
H
G
E
E33 FPI Direct Vent Gas Insert
kW
)
F
I
918-491

Advertisement

Table of Contents
loading

This manual is also suitable for:

E33-lp1

Table of Contents