2. Carefully push the power cord grommet through the
hole in the back panel (see Figure 40, CLRCO2175
shown).
Screws
Grommet
Power
Cord
Figure 40
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your
hands inside the ice maker cabinet or attempt to
touch any components except the discharge tube
during testing. Failure to follow this warning
could result in serious personal injury or death.
4. Check that the clamps and hose connections are tight at
the following areas (see Figure 41):
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
B
Back View
Figure 41
05/2007
CLR2160/CLRCO2175 Ice Makers
Back
Panel
Water
Drain
Connection
Fitting
ULIN_0574_A
C
C
A
Side View
ULIN_0575_A
5. Place a suitable container beneath the pump's discharge
tube. (The bucket must be able to hold a minimum of
one gallon.)
6. Plug the ice maker power cord into a properly
grounded, polarized electrical outlet.
7. Place the unit into OFF mode by holding power key for
10 seconds. Not doing this will cause the unit to start
the fill cycle which will run for 3 minutes.
8. Verify pump operation by pouring one gallon of water
into the ice storage bin of the ice maker. The pump
should energize and pump the water into the container.
9. At this time, verify that all tube and clamp connections
are tight and leak-free.
10. Unplug unit power cord from electrical outlet.
11. Reinstall back panel.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have
not purchased a CLR2160 or CLRCO2175 with factory-
installed pump, we strongly recommend the use of the
U-Line P60 drain pump. The U-Line P60 drain pump is
available through your Dealer, with complete installation
instructions. If a pump other than the U-Line P60 drain
pump is to be used, it must meet the following
specifications:
• It must be UL listed and have a UL listed, 120 VAC,
3-wire grounded power cord.
• It must have overall maximum outside dimensions of
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 1.5 gallons per
minute at 10 feet of lift.
• It must have a sealed sump which does not allow water
leakage in the case of a power outage, restricted drain
or pump failure.
• It must have a check valve in the discharge line to
prevent waste water return to the pump.
B
• It must have an overflow protection control which will
shut off power to the ice maker in the event of a pump
failure.
• It must have an operating temperature range of 50°F
to 110°F (10°C to 40°C).
In the event of a power outage, restricted drain or pump
failure, the failure to use the U-Line P60 drain pump or a
pump with the above listed specifications, could result in
substantial water leakage and pooling with severe and
costly water damage and related consequential damages
and harm.
17