U-Line CLR2160 Installation Manual page 16

Echelon series clear ice maker combo clear ice maker/refrigerator
Hide thumbs Also See for CLR2160:
Table of Contents

Advertisement

Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
Figure 37
• Drain line does not create traps or created traps are
vented (see Figure 37).
See Figure 38 for a typical Gravity Drain installation.
If using a Gravity Drain:
1. Slide 2 hose clamps onto the drain connection on the
rear of the appliance.
2. Insert the barbed fitting halfway into this connection.
3. On the other end of this barbed fitting attach the 5/8"
braided tubing.
4. Slide a clamp on each side of the barbed fitting as
shown (see Figure 39).
5. Insulate the drain line, if necessary to prevent
condensation. Go on to Final Water/Drain Connection
Page 18.
www.U-LineService.com
CLR2160/CLRCO2175 Ice Makers
Gravity Drain
ULIN_0569_A
Figure 38
Figure 39
Factory-Installed Drain Pump
If your drain line will run up to a stand pipe, disposal
assembly or spigot assembly or does not otherwise meet
the requirements for a Gravity Drain, you may have
ordered the CLR2160 or CLRCO2175 with a U-Line P60
Drain Pump. See Figures 42, 43 and 44 for typical
installations requiring a Drain Pump. If you need to install
a P60 Drain Pump into your unit, see Locally-Installed
Drain Pump on Page 17.
Before installing your U-Line CLR2160 or CLRCO2175 with
Factory-Installed U-Line P60 Pump, it is extremely
important to check and test all hose connections at the
drain pump. There is a possibility that hose connections
may have loosened during shipment.
To check and test hose connections:
1. Make certain the unit is not plugged into an electrical
16
5/8" x 5/8"
Barb Connector
IMPORTANT
outlet.
Waste
Shut-Off
Valve
Cold
Hot
Water
Water
Waste
ULIN_0570_A
Drain Fitting from
Back of Unit
Worm Clamps
Drain Line
ULIN_S_0166b2_A
05/2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clrco2175

Table of Contents