5. Trouble Shooting

1. Self-diagnosis Function

1.1 Error Indicator (Indoor)
• The function is to self-diagnosis air conditioner and express the troubles if there is any trouble.
• Error mark is displayed on display window of indoor units and wired-remote controller, and LED of outdoor unit control
board.
• If more than two troubles occur simultaneously, lower number of error code is first displayed.
• After error occurs, if error is released, error LED is also released simultaneously.
Ex) Error 21 (DC Peak)
10 digit
LED
1 digit
LED
1.2 Indoor Error
Error code
00
No Error
01
Indoor Room themistor error
02
Indoor in-piping sensor error
03
Remote controller error
04
Drain Pump error
05
Communcation error between in and out
06
Indoor Out-Piping sensor error
07
Differnt mode operation
09
Checksum error
10
BLDC motor fan lock (indoor)
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
1 digit
10 digit
2 Times
1 Sec.
1 Time
2 Sec.
Description
- 78 -
2 Times
1 Sec.
1 Time
2 Sec.
LED 1
INV TPS
(Red)
2 Times
1 Sec.
1 Time
LED 2
Indoor
(Green)
Status
ON
1time
OFF
2times
OFF
3times
OFF
4times
OFF
5times
OFF
6times
OFF
7times
OFF
9times
OFF
10times
OFF
LGE Internal Use Only